6. Technical data

Mains connection
Motor rating W
Operating mode
Compressor speed
Pressure vessel capacity (in
liters)
Operating pressure
Theoretical intake capacity (l/
min)
sound power level L
WA
uncertainty K
WA
Protection type
Weight of the unit in kg
Oil (15W 40) l
Max. altitude
(above mean sea level)
The noise emission values were measured in ac-
cordance with EN ISO 3744.
Wear hearing protection.
The effects of noise can cause a loss of hearing.

7. Before starting the equipment

Before you connect the equipment to the mains sup-
ply make sure that the data on the rating plate are
identical to the mains data.
Check the equipment for damage which may have
occurred in transit. Report any damage immedi-
ately to the transport company which was used to
deliver the compressor.
Install the compressor near the point of consump-
tion.
Avoid long air lines and supply lines (extension
cables).
Make sure that the intake air is dry and dustfree.
Do not install the compressor in a damp or wet
room.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient tem-
perature from +5 °C to 40 °C). There must be no
dust, acids, vapors, explosive gases or inflamma-
ble gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed water.
The oil level in the compressor pump has to be
checked before putting the equipment into opera-
tion.
230 V ~ 50 Hz
2200
S1
2850 min
-1
50
approx. 8 bar
approx. 412
97 dB(A)
2.03 dB
IP20
approx. 41
approx. 0,25
1000 m

8. Attachment and operation

m Important!
You must fully assemble the appliance before using it
for the first time!
You will require the following tools for assembly and
installation: 2 x open-ended wrench size 19 mm (not
included)
You will require the following tools for assembly and
installation: 2 x open-ended wrench size 14 mm (not
included)
8.1 Fitting the wheels (Fig. 5)
Fit the supplied wheels (11) as shown.
8.2 Fitting the supporting foot (2x)(Fig. 6)
Fit the supplied supporting foot (2x) as shown.
8.3 Fitting the air filter (2x)(Fig. 7,8)
Remove the transportation stop (A) and screw the
air filter (14) to the equipment.
8.4 Changing the transportation cover (B) (Fig.
9,10)
Remove the transportation cover from the oil filter
opening (19) and insert the supplied oil sealing
plug (15) into the oil filler opening.
8.5 Mains connection
The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to
any 230-240V ~ 50 Hz shock-proof socket.
Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
At low temperatures below +5°C, sluggishness
may make starting difficult or impossible.
8.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (16) upwards to switch
on the compressor. To switch off the compressor,
press the ON/OFF switch down.
8.7 Setting the pressure (Fig. 1,3)
Use the pressure regulator (5) to set the pressure
on the pressure gauge (4).
The set pressure can be drawn from the quick lock
coupling (3).
The vessel pressure can be read off the pressure
gauge (6).
The vessel pressure is drawn from the quick lock
coupling (7).
8.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory. Cut-in
pressure approx. 6 bar Cut-out pressure approx.
8 bar.