7.2 PV module/ PV string, open-circuit voltage, (Vo/c)
Measuring range
5.0 V - 1000 V
7.3 PV module/ PV string, short-circuit voltage, (Is/c)
Measuring range
0.50 A - 9.99 A
7.4 Insulation resistance R
Measuring range
0.20 MΩ - 100 MΩ
101 MΩ - 199 MΩ
Testing voltage:
Testing current:
Number of repetitive
tests (IEC 61557-2)
7.5 R
voltage via 4 mm test sockets
PE
Measuring range
5 V - 440 V AC/ DC
7.6 Current by means of AC/ DC current clamp adapter BENNING CC 3 (part no. 044038)
Measuring range
0.1 A - 40.0 A AC/ DC
8.

Making measurements with the BENNING PV 1

8.1 Preparations for making measurements
Operate and store the BENNING PV 1 only at the specified storage and operating temperatures
conditions. Do not permanently expose the device to sunlight.
-
Check rated voltage and rated current details specified on the safety measuring leads.
-
Strong sources of interference in the vicinity of the BENNING PV 1 can lead to unstable
readings and measuring errors.
Before starting the BENNING PV 1, always check the device, the leads and the
m
test object for damages.
8.1.1
Switching the BENNING PV 1 ON/ OFF
-
Press and hold the keys 2 and 3 for approx. 2 seconds to switch the BENNING PV 1 on.
Acoustic signals confirm that the device is switched on. Press the keys again for approx. 2
seconds to switch the device off.
-
After approx. 2 minutes, the BENNING PV 1 switches off automatically (APO, Auto Power-
Off). It switches on again when the keys 2 and 3 are pressed. An acoustic signal indicates
that the device has switched off automatically.
8.1.2
Testing the battery condition
During switch-on and operation, the BENNING PV 1 carries out an automatic battery test. Dis-
charged batteries are indicated by a battery symbol P on the LC display 1 . As soon as the bat-
tery symbol is flashing, the batteries have to be replaced immediately (see chapter 9.4, "Battery
replacement").
8.1.3
Compensation of the measuring leads (null balance)
In order to carry out a compensation (null balance) of the measuring lead resistance, connect the
measuring leads with each other by means of the alligator clips and press the
symbol C is shown on the LC display 1 .
NULL
m
Measuring lead resistances can be compensated by up to 10 ohms.
09/ 2011
Resolution
0.1 V
Resolution
0.01 A
ISO
Resolution
max. 0.01 MΩ
1 MΩ
250 V
DC
> 1 mA, < 2 mA in case of a short-circuit
Resolution
1 V
Resolution
0.1 A
BENNING PV 1
/ 500 V
/ 1000 V
DC
DC
approx. 2000
Measuring accuracy
± (0.5 % + 2 Digit)
Measuring accuracy
± (1 % + 2 Digit)
Measuring accuracy
± (5 % + 5 Digit)
± (10 % + 5 Digit)
, + 20 %, - 0 %
Measuring accuracy
(DC, AC 50 Hz - 60 Hz)
± (5 % + 2 Digit)
Measuring accuracy
(DC, AC 50 Hz - 60 Hz)
± (5 % + 2 Digit)