7.6 Frequency ranges

Overload protection for frequency measurements: 600 V
7.6.1
Frequency ranges for square wave signals (Switch setting: Hz, %)
Measuring
Resolution
range
5 Hz
50 Hz
500 Hz
5 kHz
50 kHz
500 kHz
5 MHz
7.6.2
Frequency indication for sinusoidal signals (Switch setting: V
actuation of the „SELECT" key:
Measuring accuracy: ± (0.3 % + 5 digits) applies to sinusoidal voltages of up
to 600 V
(V
) higher than 50 % of the final measuring range value
AC
7.7 Pulse duty ratio for square wave signals (Switch setting: Hz, %)
Overload protection in the case of pulse ratio measurement: 600 V
Meas. range
0.1 % - 99.9 %
8.

Measuring with the BENNING MM P3

8.1 Preparing the measurement
Operate and store the BENNING MM P3 at the specified storage and operating tem-
peratures only! Do not permanently expose the device to sunlight.
-
The connected black and red safety measuring leads comply with the valid provi-
sion, if they are undamaged.
-
Please protect the connected black and red safety measuring leads against con-
tamination and damages!
-
Check insulation of the safety measuring leads. If the insulation is damaged,
multimeter must be replaced immediately.
-
Check the safety measuring leads for continuity. If the conductor in the safety
measuring lead is interrupted, replace the multimeter immediately.
-
Before selecting another function by means of the rotary switch 7 , disconnect
the safety measuring leads from the measuring point.
-
Strong sources of interference in the vicinity of the BENNING MM P3 might involve
unstable readings and measuring errors.
02/ 2011
Measuring accuracy for 5 V
0.001 Hz
± (0.3 % of the measured value + 5 digits)
0.01 Hz
± (0.3 % of the measured value + 5 digits)
0.1 Hz
± (0.3 % of the measured value + 5 digits)
1 Hz
± (0.3 % of the measured value + 5 digits)
10 Hz
± (0.3 % of the measured value + 5 digits)
100 Hz
± (0.3 % of the measured value + 5 digits)
1 kHz
± (0.3 % of the measured value + 5 digits)
(10 Hz - 500 Hz) and displayed values in the AC voltage range
eff
Resolution
0.1 %
± (0.5 % of the measured value + 3 digits) > 1.0 V
BENNING MM P3
(square wave signal)
Measuring accuracy up to 5 V
(square wave signal, 5 Hz - 5 kHz)
eff
max.
Sensitivity
SS
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
> 1.0 V
, Hz, %) and
AC
eff
Sensitivity
SS
(30 % ≤ % ≤ 70 %)
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
(rectangle)
ss
18