Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Technical Data For Pp 45; Technical Data For Ppb 30 - Maico PP 45 O Installations- Und Inbetriebnahmeanleitung

Pushpull lüftungssysteme
Vorschau ausblenden Andere Handbücher für PP 45 O:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

UK | 5 Technical data

5 Technical data

5.1 Technical data for PP 45

External diameter
Wall sleeve max. length 500 or 800 mm
Wall thickness min.
max.
Air filter outside
Air filter inside
Air volume/unit
Protection class
degree of protection
Sound pressure level:
at distance of 1 m
free-field conditions
(ventilation levels 1 to 5)
Rated voltage/
power frequency
Volumetric flows for
ventilation levels 1, 2,
3, 4, 5
Power consumption
Permissible ducting
lengths
with wired
connection
Weight
slide-in module cpl.
Radio components:
Frequency range (in acc.
with EN 300220-1)
"Wireless" operating
distances in the building
are dependant
on the building materials
used:
DS 45 RC  PP 45 RC
PP 45 EO  PP 45 RC
PP 45 RC  PP 45 RC
● With PP 45 RC as
signal booster
42
DN 160
265 mm
490 / 790 mm
G3
G2
42 m³/h
IP 00
2
23 / 28 / 33 /
37 / 40 dB(A)
230 V
50/60 Hz
15 / 20 / 30 /
36 / 42 m³/h
1.2 / 1.7 / 2.1 /
2.8 / 3.5 W
From star point
max. 25 m per
ventilation unit
3 kg
868.35 MHz
up to:
30 m
30 m
30 m
40 m

5.2 Technical data for PPB 30

External diameter
Wall thickness
Wall sleeve
(max. length)
Air filter
Air volume/unit
Degree of protection
Sound pressure level,
at distance of 1 m
free-field conditions
(ventilation levels 1 to 5)
Rated voltage/
power frequency
Volumetric flow
heat recovery mode
ventilation level 1 to 5
Volumetric flow, exhaust
air mode (no heat
recovery)
Power consumption
(ventilation level 1 to 5)
Degree of heat provision 73.3 % (level 3)
SPI
SEC value
Permissible ducting
lengths with wired
connection
Weight slide-in
module cpl.
Radio components:
Frequency range (in acc.
with EN 300220-1)
"Wireless" operating
distances in the building
are dependant on the
building materials used:
DS 45 RC  PP 45 RC
PP 45 EO  PP 45 RC
PP 45 RC  PP 45 RC
● With PP 45 RC as
signal booster
DN 160
320 - 790 mm
PP 45 RHK: 500 mm
PP 45 RHL 800 mm
G3 (2 items)
26 m³/h
IP X4
18 / 32 / 41 /
45 / 49 dB(A)
230 V
50/60 Hz
5 / 12 / 18 /
22 / 26 m³/h
45 m³/h
1.7 / 2.5 / 3.4 /
4.4 / 5.3 W
0.19 W / (m³/h)
A (-39.71 kWh / (m²*a))
From star point max.
25 m per ventilation unit
3.6 kg
868.35 MHz
up to:
30 m
30 m
30 m
40 m

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis