gb │ Product information, Technical data, Safety instructions, Mounting

2.3 Intended use

Use air opening:
● as supply air component in central or de-
centralised domestic ventilation systems.
● for fresh air supply in living or bedrooms.
● in outside walls.
● in normal mode with open air opening.
● when external air is polluted (e.g. smell
of burning), with closed internal shutter.

2.4 Foreseeable cases of misuse

Maico is not liable for damages caused by use
contrary to the intended purpose. Under no
circumstances should the unit be used:
● if installed in incorrect position. If sloped
towards the inside wall, any condensate
produced may run into the interior of the
building.

3. Technical data

Max. standard sound
level difference D
n,w
500 mm
length of
Volumetric flow at
8 Pa differential pressure
and G2 air filter
Wall thickness
Core hole diameter
needed
Further technical data
● Rating plate [4.1]
● Dimensions and characteristics curves
 Appendix
● Internet  maico-ventilatoren.com or
using the QR code on the fold-out page

4. Safety instructions

● Mounting is only permitted when carried
out by trained specialists.
● If the outside air is polluted, the internal
shutter [5] must be closed manually to
prevent the pollutants entering the
building.
10
ALD 125: 47 dB
with
ALD 160: 53 dB
ALD125: 24 m³/h
ALD160: 24 m³/h
up to 500 mm
ALD 125: 127 mm
ALD 160: 162 mm
● The applicable accident prevention re-
quirements must be observed. Work with
an awareness of the safety requirements
and associated risks, especially when
working at height, for example when
mounting the external grille.
● Only use genuine Maico accessories.
● Adjustments to structural circumstances are
permitted as described below. Additional
modifications and alterations to the ALD are
not permitted and release Maico from any
guarantee obligations and liability.

5. Mounting

5.1 Mounting instructions

● Position outside wall air opening as per
the details of your planning office.
● Install ALD at an incline of around 1...2 %
to the outside wall.
● Recommendation: Install ALD in top part
of window (to right or left of window) at a
height of 2 to 2.20 m.
● It must be possible for the designer cover
[1] to be removed in order to change the
filter. The mounting site should be
selected accordingly.
● Thinner walls will mean reduced sound
insulation.
● Together the three sound-absorbing
elements must be of the same length as
the wall sleeve [11] (otherwise sound
insulation is reduced).
● You will find more information and
planning tips in the Practical guidance for
comfort ventilation, chapter 3.8
( maico-ventilatoren.com, service,
download product documents, controlled
domestic ventilation).
5.2 Preparations for mounting
1. Take outside wall air opening out of
packaging.
2. Remove complete inner part (items [1]
to [8]) from wall sleeve [11].
3. Remove complete outer part (items [12]
to [14]) from wall sleeve [11].