6 Technical data

Ventilation solution for a 3-room flat with PPB 30
K ventilation units for the bathroom and PP 45
ventilation units for living spaces. The PPB 30 K
ventilates and extracts air from the bathroom, at
the same time, with balanced operation. A PPB
30 K fan ventilates the room with air which has
been pre-warmed in the heat exchanger. The
other PPB 30 K fan transfers the thermal energy
from the exhaust air to the heat exchanger during
air extraction. Every 60 seconds, the air direction
changes, thereby permitting a ventilation mode
with constant heat recovery. In case of high air
humidity, intensive ventilation can be activated via
a humidity sensor (automatically) or manually with
a button. Pure exhaust air mode is also possible
and here the two fans pump humidity out of the
room (no heat recovery).
6 Technical data
6.1 Requirements at the installation
site
• Ambient temperature - 15 °C to + 40 °C.
• Airstream temperature, max. 40 °C.
• Max. permissible humidity in installation room
PP 45: 70 % / PPB 30: 90 % (at 20 °C).
• A level and solid wall surface is needed for wall
installations.
NOTICE: Conveyance of structure-borne
sound if core drill hole touches door/window
lintels or ring beams. Observe spacing
between core drill hole and door/window lin-
tels and ring beams.
• Exterior wall with sufficient load-bearing capa-
city (min. 200 kg/m³).
• For filter changes, ensure sufficient space to
work in front of the unit.
• Do not drill core drill hole for unit assembly and
do not drill fixing points on external and internal
covers in load-bearing components, such as in
the lintel or ring beam.
26

6.2 Technical data table

6.2.1 Technical data for PP 45

External diameter
Wall sleeve
max. length
Wall thickness min.
Wall thickness max.
Rated voltage
Power frequency
Permissible ducting
lengths with wired
connection
For more technical data → rating plate.
For characteristic curves → www.maico-ventil-
atoren.com

6.2.2 Technical data for PPB 30

External diameter
Wall sleeve
max. length
Wall thickness min.
Wall thickness max.
Degree of protection
Rated voltage
Power frequency
Permissible ducting
lengths with wired
connection
For more technical data → rating plate.
For characteristic curves → www.maico-ventil-
atoren.com
DN 160
PP 45 RHK: 500 mm
PP 45 RHL: 800 mm
265 mm
490 or 790 mm
230 V
50/60 Hz
From star point max.,
25 m per ventilation unit
DN 160
PP 45 RHK: 500 mm
PP 45 RHL: 800 mm
320 mm
790 mm
IP X4
230 V
50/60 Hz
From star point max.,
25 m per ventilation unit