6. Safety instructions

WARNING
Risks for people (including
children) with reduced
physical, sensory or mental
capabilities or a lack of
knowledge.
Only have internal shutters
be installed, commissioned
and cleaned by people who
can safely recognise and
avoid the risks associated
with this work.
DANGER
Danger from electric shock.
Before removing the cover
[8], shut down all supply
circuits, deactivate the mains
fuse and secure them so they
cannot be switched back on.
Attach a warning sign in
clearly visible place.
NOTICE
Unit damage if ventilation
slots are covered or
blocked.
Always keep ventilation slots
clear. Do not cover them.
6. Safety instructions │ UK

7. Function/Operation

Rooms are aerated or ventilated with the set
basic and maximum ventilation.
Internal shutters can be controlled with
standard on/off switches, timers or follow-up
relays.
The operating indicator light lights up when
unit is switched on. The internal shutters
open/close with a delay.
For information regarding cleaning  Chap-
ter 15. Otherwise, the internal shutters are
maintenance-free.

8. Technical data

 Rating plate on the unit.
Nominal size AE 10
AE 16
Type of installation
Rated voltage
Power frequency
Degree of protection
Weight AE 10 / AE 16
Dimensions, with
sockets
(W x H x D)
AE 10
AE 16
9. Environmental conditions and
operating limits
Ambient temperature max. +40 °C.

10. Storage

Store unit exclusively in a dry location
(-20 to +50 °C).
Ø 100
Ø 150
Surface-mounted
230 VAC
50 Hz
IP 20
0.2 kg / 0.3 kg
146x146x60 mm
202x202x60 mm