Securing the appliance to the
cabinet

Electrical installation

The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied with a main
plug and a main cable.

ENERGY EFFICIENCY

Product Fiche and information according to EU 65-66/2014
Supplier's name
min. 550
20
18
590
min. 560
5
3
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-
A
F, H05 V2V2-F (T90), H05 BB-F
B
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
548
21
114
589
594
+-1
595
Total power (W)
maximum 1380
maximum 2300
maximum 3680
Juno
198
523
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5