Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation - JUNO JH094C9 Benutzerinformation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Building In
80
60
520
60
20
Securing the appliance to the
cabinet

Electrical installation

The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied without a main
plug and a main cable.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F
min. 550
20
600
min. 560
5
3
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
A
B
Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
548
21
114
18
589
594
+-1
595
Total power (W)
maximum 10380
1
198
523
Section of the ca‐
ble (mm²)
3 phases: 5 x 2.5
2 phases: 4 x 4.0
1 phase: 3 x 6.0
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
2
3
4
29

Werbung

Kapitel

Inhaltsverzeichnis
loading