IKM360R
Technical data
Changing the angle position
1. Turn on insert, slightly pull out and rotate to desired angular position
2. Screw on insert.
7.4 Mating connector M12 bus terminator
• Accessory SIKO art. no. "82815" (pin 5 pole Bus OUT).
8 Technical data
Mechanical data
Housing
Mounting type
Weight
Electrical data
Operating voltage
Current consumption
Status display
Power rating
Temperature drift
Interface
Address
Baud rate
Starting time
IKM360R · Date 21.01.2021 · Art. No. 90437 · Mod. status 222/20
(in steps of 45°).
plastic/stainless steel
3-point mounting
~0.149 kg
8 ... 36 V DC
≤100 mA
2x two-color LEDs (red/
green)
±36 V
≤0.02 °/K
typical 0.008 °/K
according to ISO 11898-1/2,
not electrically isolated
according to ISO 11898-1/2,
not electrically isolated
1 ... 127
20 kBit/s
50 kBit/s
125 kBit/s
250 kBit/s
500 kBit/s
800 kBit/s
1 MBit/s
<150 ms
(Fig.
4)
Additional information
Additional information
reverse-polarity protected
without load
Device status/CAN status
CAN interface
CANopen, CiA 301, CiA 303 Part
3, CiA 305, CiA 410
CANopen Safety,CiA 301, CiA
303 Part 3, CiA 305, CiA 410, EN
50325-5
Node ID, parameterizable via SDO
or Layer Setting Service (LSS)
English
21