About indicator status
■ When there is a problem with the shutter
z
The status of the indicator is displayed with the following symbols.
L: Off, G: On, #: Flashing, I: On or Flashing
<STAND-
<POWER>
BY>
Green
Red
*1
*1
I
I
*3
L
#
L
G
*1: The indicator will change according to different conditions, regardless of the status of other indicators.
*2: The indicator will flash in approximately 0.5-second intervals.
*3: The indicator will flash in approximately 1-second intervals.
Note
z The status of each lamp can be checked as the lamp indicators (<LAMP 1 REPLACE> to <LAMP 4
REPLACE>) at the top of the projector turn on or flash. (
82 - ENGLISH
Indicator
<WARNING
<WARNING
<SHUTTER>
TEMP.>
FILTER>
Blue
Red
Orange
*1
*1
*2
I
I
#
*2
L
L
#
*1
*2
L
I
#
<LAMP
Status of the projector
REPLACE>
Orange
The shutter cannot be opened or closed. The lamp will
turn off, cooling will begin and the projector will switch
to the standby mode. The power will turn on and the
projector will attempt to open the shutter automatically
*1
I
up to three times. After three failed attempts, the
projector will switch to the standby mode after the
lamp has cooled.
There is a problem with opening or closing the shutter,
*1
I
and the lamp has turned off and is cooling down.
There is a problem with opening or closing the shutter,
and projector will switch to the standby mode after the
*1
I
lamp has turned off and cooled down.