Herunterladen Inhalt Inhalt Diese Seite drucken

Christie LX1750 Bedienungsanleitung Seite 65

Vorschau ausblenden Andere Handbücher für LX1750:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 215
[Setting] menu
■ To check [Measured]
z
Displays data for R/G/B.
1) Press ▲▼ to select the color ([Red]/
[Green]/[Blue] in [Measured]) to be
measured.
2) Press the <SELECT> button.
3) Press ▲▼ to change the value, and
press ◀▶ to move between digits.
z
z The numerical values can also be entered using
the number (<0>-<9>) buttons of the remote
control.
Color
[Red]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Green]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Blue]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
■ To check [Target]
z
1) Press ▲▼ to select the color ([Red]/
[Green]/[Blue]/[Cyan]/[Magenta]/
[Yellow]/[White] in [Target]) to be
adjusted.
2) Press the <SELECT> button.
3) Press ▲▼ to change the value, and
press ◀▶ to move between digits.
z
z The numerical values can also be entered using
the number (<0>-<9>) buttons of the remote
control.
z
z The numerical value changes according to
the value of [Color temp.] in the [Image adjust]
menu.
Color
[Red]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Green]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Blue]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Cyan]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Magenta] 0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[Yellow]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
[White]
0.000 - 1.000 0.000 - 1.000 0.000 - 1.000
64 - ENGLISH
x
y
x
y
■ To display the test pattern
z
1) Press ▲▼ to select [Auto test pattern].
2) Press the <SELECT> button.
3) Press ▲▼ to switch the setting.
z
z Press the <SELECT> button to end the edit
mode.
[Off]
[On]
■ To temporarily clear the setting
z
screen
L
1) Press ▲▼ to select [Menu off].
2) Press the <SELECT> button.
z
z Press any button to return to the setting screen.
■ To perform [Factory default]
z
setting
When the currently selected [Measured] and
[Target] are reset, the values are returned to the
factory default settings.
1) Press ▲▼ to select [Factory default].
2) Press the <SELECT> button.
z
z A screen for confirming whether to restore the
default setting is displayed.
3) Select [Yes], and press the <SELECT>
button.
z
z The confirmation screen is displayed.
4) Select [Yes], and press the <SELECT>
button.
g
■ To reset a value during
z
adjustment
The setting returns to its value before adjustment.
1) Press ▲▼ to select [Reset].
2) Press the <SELECT> button.
3) Select [Yes], and press the <SELECT>
button.
Clears display of test pattern.
Displays the test pattern.
LX1750 User Manual
020-000638-01 Rev.1 (11-2013)