Herunterladen Inhalt Inhalt Diese Seite drucken

Hilti PS 200 Bedienungsanleitung Seite 43

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Depth (mm)
20
40
50
60
#3
±2
±2
±2
±3
#4
±2
±2
±2
±3
#5
±2
±2
±2
±3
#6
±2
±2
±2
±3
#7
±2
±2
±2
±3
#8
±2
±2
±2
±3
#9
±2
±2
±2
±3
#10 ±2
±2
±2
±3
#11 ±2
±2
±2
±3
Depth (inch)
0.8
1.6
2.0
2.4
#3
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#4
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#5
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#6
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#7
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#8
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#9
±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#10 ±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
#11 ±0.1 ±0.1 ±0.1 ±0.1 ±0.15 ±0.2
Depth (mm)
20
40
50
60
#10 ±2
±2
±2
±3
#15 ±2
±2
±2
±3
#20 ±2
±2
±2
±3
#25 ±2
±2
±2
±3
#30 ±2
±2
±2
±3
#35 ±2
±2
±2
±3
Depth (mm)
20
40
50
60
6
±2
±2
±2
±3
10
±2
±2
±2
±3
13
±2
±2
±2
±3
16
±2
±2
±2
±3
19
±2
±2
±2
±3
22
±2
±2
±2
±3
25
±2
±2
±2
±3
29
±2
±2
±2
±3
32
±2
±2
±2
±3
35
±2
±2
±2
±3
38
±2
±2
±2
±3
4.3 Specifications
Maximum scanning speed
Memory type
Memory capacity
Screen type/size
Screen resolution
Dimensions
Weight (with PSA 80 battery)
Printed: 07.07.2013 | Doc-Nr: PUB / 5070389 / 000 / 00
80
100
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
3.1
3.9
80
100
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
80
100
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
±4
±5
PS 200 S scanner
0.5 m/s
Built-in data flash memory
9 Imagescans plus up to 30 m
of recorded Quickscan
(max. 10 scans)
LCD/50 × 37 mm
128 × 64 pixels
260 × 132 × 132 mm
1.40 kg
Depth (mm)
20
40
50
8
±2
±2
±2
10
±2
±2
±2
12
±2
±2
±2
14
±2
±2
±2
16
±2
±2
±2
18
±2
±2
±2
20
±2
±2
±2
22
±2
±2
±2
25
±2
±2
±2
28
±2
±2
±2
32
±2
±2
±2
36
±2
±2
±2
Value indicates typical accuracy of depth measurement
(deviation from actual) in mm or inches as applicable.
d. Quickscan detection
Depth measurement is typically accurate to within ±10 %
of the effective depth.
4.2.2 Accuracy of bar diameter measurement
±1 standard diameter when rebar spacing: depth of cover
≥2 : 1. Bar diameter measurement is possible only at
depths of up to 60 mm.
4.2.3 Accuracy of rebar location
Relative bar center measurement accuracy (all modes),
typical: Typically ±3 mm or typically ±0.1 inch relative to
the measured position, when the bar spacing: depth of
cover ≥1.5:1.
PS 200 M monitor
--
Removable SD card, max. memory
card size: 1 GB
At least 150 Imagescans or 75 Quick-
scans (total 2250 m), plus up to
15 minutes of speech with 32 MB
card.
LCD/115 × 86 mm
320 × 240 pixels/16 gray scales
264 × 152 × 57 mm
1.40 kg
60
80
100
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
±3
±4
±5
en
41

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis