The control unit switch

The control unit switch can be found on the
top end of the unit. Using this
switch, you can isolate the electronics from
the mains supply in case of a breakdown.
Please note that operating the control unit
switch returns all settings to the factory
settings.
In case of breakdown, press the control unit
switch on the left part of the rocker to the
fi rst position (switch position 0). The unit is
now completely switched off.
In order to switch on the light in the sauna
when the unit is switched off, press on the
left part of the rocker to the second position
(switch position II).
In order to put the unit back into operation,
switch back to the starting position (switch
position I).

Error display

To quickly diagnose possible errors, use the error code explanation below to ascertain the
type of error.
Error code
Error
E 100
temperature sensor interruption/disconnection
E 101
temperature sensor short circuit
E 211
overheat safety shutoff interruption/disconnection
The warning symbol
recognize an error.

Additional errors not displayed and their causes:

Blank display - display not backlit
Check the power supply! All three phases L1, L2, L3 must be connected to 230 V AC.
Check all fuses.