Assembling the control unit

The control unit must not be as-
sembled inside the IR cabin.
• The control unit (ArtNo.: 94.4334) is prein-
stalled for plug-in electrical connection.
• The control unit has the following con-
nector cables:
Power line to grounding type plug
Connector cable for IR radiator
Connector cable for cabin lighting
Sensor line (red)
• The connector cable to the IR radiator
is equipped with a plug part which is fed
into the in the junction socket as a lead
wire. From there you have 5 connection
options for IR radiators.
• The control panel without wiring and ca-
bles (item no. 94.4388) is supplied not
pre-mounted.
The delivery includes:
Sensor cable (red)
• Not included are (to be supplied, instal-
led and connected at site):
Power supply cable (mains)
Connection cable for IR radiators
Connection cable for light
• When more than one IR radiator should
be installed, they should be connected
via a separate distribution box (multi-
connector). Only one cable may be con-
nected to the control panel
• But make sure the maximum radiation out-
put does not exceed 3.5 kW.
• The connector cable for cabin lighting is
connected to the cabin lighting in the ca-
bin (max. 100W).
• First, suitably position the wall opening on
the exterior of the cabin at eye level next
to the door. The opening must be 178 mm
wide and 114 mm high.
The installation depth is 45 mm.
• Feed the connector cables through the
space between the cabin wall and the cei-
ling.
• If the cables cannot be laid inside the cabin
wall they must be placed inside the cabin.
45 mm
GB
178 mm
181 mm
45 mm
19