9.2

Selecting and changing the nosepiece

Attention: Always use a nosepiece corresponding to the blind rivet size (selection according to table point 6.)
Exchanging nosepieces:
Disconnect the tool from the compressed air.
Unscrew the nosepiece from the tool head.
Screw in and tighten the replacement nosepiece.
9.3

Setting a blind rivet

Connect the tool to the compressed air..
Insert the blind rivet into the nosepiece and place the rivet into the workpiece
Press the yellow trigger until mandrel breaks.
Release the yellow trigger.
The mandrel is automatically transported to the mandrel container (see point 9.5).
9.4

Suction and holding of a blind rivet

This feature allows the blind rivet to be held in the tool nosepiece for vertical, downwards riveting.
Open the ON/OFF valve N° 66 in the tool head by pushing it to the right or left stop with a pin (e.g. a
mandrel) to enable the suction feature.
After Closing the hand on the pistol grip push slider N° 68 upwards to stop to switch on the suction.
Pushing slider N° 66 downwards will switch off the suction.
Pushing back the ON/OFF valve N° 88 will permanently disable the suction feature.
9.5

Emptying the mandrel container

The mandrel container must be emptied regularly; Overfilling causes the tool to malfunction.
Unscrew the container counter-clockwise and dispose of spent mandrels according to valid recycling procedures.
Screw the spent mandrel container back on to the tool

10. Operating Software

The setting process monitoring is set with the Gesipa GRivCheck proprietary software. The software does not
have to be installed; it can be started by double-clicking directly on the PC connected to the tool. After starting
the operating software the processing tool automatically connects to the PC and the start screen opens as
soon as the connection is established. If no connection can be made because the connection port to the PC is
not set correctly, the port setting must be carried out as described in chapter 4.5. In the start screen, the area
processing tool shows the serial number of the connected processing tool. The start screen is divided into the
areas processing tool, setting, operating mode, archive and setting, (illustration 3). The manual is called up via
the help function. The language setting German, English or French can be carried out in the Setup menu.