4.

Technical Data

Tool
Type of tool
Weight ca.
Operating pressure
Stroke
Air connecting hose Ø
Spent mandrel container capacity
Air consumption [l/rivet]
Setting Power at 5 bar
Hydraulic fluid ISO VG 32 up to 46
Noise emissionLpa
Vibration
Compressed air requirement (filtered)
Integrated spent mandrel ejection
Integrated rivet retention
Prozessdatenmodul
Power supply
Permitted supply voltage range
Power input
Behavior in case of failure of supply voltage
Lifetime of support battery (CR2032) for Real time
clock, type.
Interface
Transfer rate interface
Protocol interface
Hardware handshake
Process data memory
Profile data memory
Temperature range
Safety class
TAURUS
1 C
TAURUS
®
2.3 kg
2.4 kg
5-7bar
5-7bar
15mm
18mm
6mm
6mm
ca. 100 – 200 spent mandrels acc. To size
approx. 1,0
approx. 2,3
4200N
9000N
approx. 30ml
approx. 30ml
77
78
<2.5m/s²
<2.5m/s²
24Volt DC (No galvanic separation in the tool)
Automatic data recovery after power failure
8 data bits, 1 stop bit, parity even
max. 260000 process data records
2 C
TAURUS
3 C
®
®
2.8 kg
5-7bar
25mm
6mm
approx. 4,8
14000N
approx. 30ml
79
<2.5m/s²
10-30Volt
1.5Watt
5 years
RS232
1200Baud – 115200Baud
CTS/RTS
224 profiles in 10 profile lists
0-50°C
IP 20
GB
TAURUS
4 C
®
2.9 kg
5-7bar
19mm
6mm
approx.. 4,8
20000N
approx. 30ml
79
<2.5m/s²
43