505
Topping up
Caution! Disconnect the unit from the mains before topping up (pull the
plug out of the socket).
• Pour fresh water into the aerosol discharge hood or into the deliming cap
(accessory "Z70"), respectively. Watch the level indicator:
– water reservoir half full:
grey mark on level indicator is in view.
– water reservoir full:
red mark on level indicator is in view.
If you wish to refill the Condair 505 directly from the tap, remove the
atomizer unit and the support disk from the reservoir. Pour water into the
reservoir. Do not exceed the imprinted level mark (corresponding to
the maximum filling height when the unit is reassembled). Then mount
the support disk and the atomizer unit.
Caution! Do not overfill the reservoir (watch the maximum level mark)
as this may affect correct operation.
Caution! Use only fresh tap water or partly/fully demineralized water.
Caution! When using additives make sure they do not affect health (con­
sider long­term effects, too). Buy certified products only.
Do not use additives based on essential oils because the may cause
damage to the plastic parts of the humidifier.
Setting the unit into operation
• Check the unit for possible damage.
Caution! If the unit is damaged do not set it into operation.
• Make sure the operating voltage of the Condair 505 (see type plate on unit)
matches the local supply voltage, then connect the unit to the mains.
The Condair 505 starts humidification without delay.
Operation
In daily operation the water level and the humidity must be monitored on a
regular basis. For monitoring the humidity we recommend to use a hygrometer
(e.g. the Condair hygrometer) placed in a suitable location (not too close to
the humidifier). Disconnect the unit from the mains as soon as the desired
level of humidity is obtained.
Please consider the following directional temperature and humidity values
for optimal humidification:
Room temperature
1 °C
20 °C
22 °C
Note: For semiautomatic (Condair 505) and fully automatic operation
(Condair 505 S) use the appropriate humidifier together with the humidistat
H-. The humidistat H­4 switches the humidifier on and off depending on the
selected nominal humidity. The humidistat H­4 is supplied with a separate
installation manual.
Setting the unit out of service
Disconnect the humidifier from the mains. Empty the water reservoir, then
clean the unit following the instructions given in chapter 6.