Herunterladen Inhalt Inhalt Diese Seite drucken

Welding Torch Cooling / Coolant Jpp - Jackle tecMIG 450 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

34. Welding torch cooling / coolant JPP

Maximum pressure: 3,2bar
Way of functioning
The welding torch coolant cooling is based on the function of a recooling plant: the cooling liquid is cooled down
to approximately room temperature via heat exchanger, with the help of the room air which is circulated by the
fan.
Water-cooled torch
The torch is cooled by a built-in low-noise, pump operated, water-cooling system. The water tank should be kept
almost full. In case of loss of water due to exchange of torch or hose sections, Check water level in the tank.
Water flow monitoring
In cooling water and flow deficiency (less than 0.25 l / min), a sensor turns off the control and display the error
message ‚ Err H2o ---‚.
After the cause is corrected for the water deficiency, the machine must switch off and on.
Water flow test
By pressing the button l/min, the water pump is activated, while the right display shows the current water flow
rate (e.g., 1.15 L / min).
If the value is less than 0.25 l / min, an insufficient water flow is present, and after 5 seconds, the pump is turned
off automatically. Troubleshooting Chapter 32 – error.
- ONLY use JÄCKLE coolant JPP (Order No. 900.020.400)
- Unsuitable coolants can cause property damage and loss of warranty.
- Do not mix with water or other coolant.
- Do not weld without cooling water! Tank must always be full.
- Pump must not run dry, not even for a short time. Deaerating the pump.
- Hazardous to health – keep away from children!
MATERIAL SAFETY DATA on
- Frost-resistance up to -30°C
Operating manual
www.jaeckle-sst.de
tecMIG 450/600
available.
Page 49

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tecmig 600

Inhaltsverzeichnis