Herunterladen Inhalt Inhalt Diese Seite drucken

BADU Profi Eco VS Bedienungsanleitung Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 64
B
For special voltages and/or the 60 Hz version, the performance
data can be taken from the pump name plate. With some special
types or motors there is no GS approval – GS approval on pump
name plate where applicable.
The pump has a permanently magnetic motor and is electronically
protected against overload.
Connecting external switch contacts
The pump has a 5-wire cable with open ends for external control.
Assignment of the cables to the individual speeds is as follows:
The cables must be connected potential free. Only switch the
contacts individually (observe priority of the contacts).
Otherwise the desired speed is not activated.
W90.13.002-2-P
NOTICE
The motor speed is switched on using the manual button or
external switch contacts. The switch contacts and the assigned
speed are activated.
If the pump starts from a standstill, it starts up in priming mode
and subsequently with the selected fixed speed.
During running operation the pump is started up to the fixed speed
directly, without priming time.
If external control is not necessary, the cable ends need to be
insulated.
EN 16
WG27.50.003-2-P
Brown
= n 1
Green
= n 2
White
= n 3
Red
= Stopp
Black
= GND
e.g. 3-channel-
timer with
potential free
GND
switch contacts
05|2017

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading