er's instructions. If the barcode for the fitting contains information about the cooling time, this is
displayed after ending the welding process. The cooling time is also displayed for simplified
presentation as a status column. The cooling time can be ended at any time by pressing the
>STOP< button. Breaking off of the cooling process will be noted in the log. Also separation of
the fittings from the connections leads to breaking off of the cooling time.
If the welding is faulty, the message "Error" appears in the display. An acoustic and a visual sig-
nal in the form of a red flashing LED is issued.
A new data entry can be started using the >arrow to the left<.
7.4

Transfer of the stored welding protocol

Press the multi-function key >USB< on the Start screen.
The logs can be transferred from the internal memory of the device to a USB memory medium
using the "USB" menu point.
Insert a USB stick into the USB connector. Wait until the storage medium was successfully rec-
ognised. This is displayed with the respective representation. Upon actuation of the >Start< but-
ton all logs stored in the device are transferred the USB stick. The device creates a new directo-
ry with the name "ROFUSE" on the USB stick. In a sub-directory of "ROFUSE", a further directo-
ry is created with the serial number of the device as a name. The logs are stored in this directo-
ry.
The logs can be managed using the read out software RODATA 2.0 and also further processed
(see Section 9).
7.5

Configuration of the device ("SETUP")

Press the multi-function key >SETUP< on the Start screen.