VARYSCAN 4 COMPACT PLUS 575 HMI
For example: DMX-address "45"
32 + 8 + 4 + 1
SW6 SW4 SW3 SW1
on
All remaining DIP-switches SW9 SW8 SW7 SW5 SW2 stay in position "OFF".

Changing of gobos

Open the lid with the label Varyscan
should unscrew the silver screws on the side of the Varyscan
gobos at the gobo wheel out of their holder and then put in other gobos. Take care that the gobo engages exactly
with it's slits in the holder. If the gobo is put in correctly, it moves easily inside the holder. Now you can close the lid.

GOBO measurements

®
With your Varyscan
, you have the chance of using two different gobo sizes.
1. Gobos JB-size
Outside diameter:
Use diameter: 28,13 mm
The three slits are placed in an angle of
120° and they are 3,2mm long and 1mm
deep
2. Standard size (E-size)
Outside diameter:
Use diameter: 28,13 mm