Herunterladen Diese Seite drucken

Technical Data; Change Of Eprom/ Software Update; Plan Of Current Circuits For Varyscan; Compact Plus 575 Hmi - JB-Lighting VARYSCAN 4 COMPACT PLUS 575 HM Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

VARYSCAN 4 COMPACT PLUS 575 HMI
Position of sockets see page 5
DMX-IN
Pin1:
ground
black
Pin2:
DMX-
beige
Pin3:
DMX+
red
Pin4:
frei
Pin5:
+ 5V
green

Technical data

Measurements:
Weight:
Power consumption:
Mains Voltage:
Bulb
:
Fuse:

Change of Eprom/ Software Update

To change the Eprom proceed as follows:
Remove the cover sheet for the electronic board below the mirror by taking out the 4 screws (see sketch page 4).
By comparing the electronic board with the plan of electronic parts you can see the Eprom at the right side (IC U2).
Carefully lever the used Eprom from the holder and exchange it for a new one.
Direction:
Pay attention to the polarity of the Eprom!
(The inlet of the Eprom has to point to the same direction as the inlet of the IC-holder.)
Close the lid and fix it with screws. Plug in your Varyscan

Plan of current circuits for Varyscan

DMX-OUT
Pin1:
Pin2:
Pin3:
Pin4:
Pin5:
hight
65 cm
width
27 cm
depth
29 cm
19 kg
1725 W
230V 50Hz 7A
Osram 575 HMI
8 ampere inert
ground
DMX-
DMX+
frei
frei
®
and please test all functions.
®

4 Compact Plus 575 HMI

35
black
beige
red

Quicklinks ausblenden:

Werbung

Kapitel

loading