Unpacking of the Varyscan
Check, if the delivery contains all parts.
Should you notice a damage through transportation, please inform immediately the carriers respectively your
dealer. Also in case of noticing missing parts.

Put in/ Exchange of the Bulb

Warning: Before opening pull out mains plug!
Loosen the screws at the lid of your Varyscan
Compact Plus 575 HMI). You can see the bulb holder in the back third of your
®
Varyscan
(see sketch page 4). Now detach nuts No.1 and No.2 and remove
the bulb from it's holder. Put the new HMI bulb into the holder and tighten nuts
No.1 and No.2 by hand. The point on the glass of the bulb should on no
account point to the concave mirror, respectively to the lenses (sketch page
4), it should point to the base sheet or to the lid. Take care that the bulb is
tightened in the holder.
Warning: Never touch the glass of bulb of the 575 HMI bulb itself !
An adjustment of the bulb is not necessary.

Mounting of Mirror

Take the mirror with the metalsheet, put it on the y-motor and close the screws.

Starting the Equipment

1. Hang up of Varyscan
To scoop the optimal functioning of your Varyscan
2. Adjustment of Varyscan
All spots should hang in the same angle, i.e. the imagined angle between perpendicular and Varyscan
the same among all Varyscans*.
®
3. Cabling of Varyscan
Power supply:
A specialist should attach a plug to the open end of the connecting cable, or have the cable connected to 230 Volt
50 Hertz.
DMX-cabling:
Connect the output of your DMX-controller with the first Varyscan
aid of a 5pole XLR-cabel. Now establish the connection between the Varyscans
cables. Make sure that in DMX-out of the last Varyscan
between pin 2 and pin 3) plugged into.
4. Adjustment at DIP-switches
At DIP-switch No.1 and No.2 you have the following possibilities of adjustment:
• initialisation mode
• test mode
®
equipment
®
Varyscan
4 Compact Plus 575 HMI
operating instructions
®
®
®
with a suitable screw-driver and lift the lid (label Varyscan
®
, you should hang up the spots as high as possible.
®
(controller DMX-out; Varyscan
®
there is a resistor (XLR-plug with a resistance of 100 Ohm
25
®
®
DMX-in) with the
®
with the aid of further 5pole XLR-
®
4
should be