Troubleshooting

In purchasing the Mc Crypt USB Mixer, you have acquired a reliable product which has been designed using state-
of-the-art technology.
Nevertheless, problems or faults may occur.
Therefore, we would like to describe here how to eliminate possible faults:
Please observe the safety instructions!
Device does not work after the mains switch POWER has been switched on:
The power pack unit has not been plugged into the socket correctly
The mains socket is not supplied with current
The mixer is turned on but no tone can be heard:
No input signal;check signal source.
Wrong input selected; select proper input.
Input level wrongly set; adjust level as described at „Setting the volume".
No signal can be heard although the level display indicates a signal:
Downstream device (amplifier) not switched on or incorrectly set
The output is not or wrongly connected.
There is a humming sound:
The record-player earth cables are not connected to the ground screws (18).
A buzz loop arises between the connected devices Connect the signal mass with special ground-insulated
cables.
A channel does not work:
A connection cable has come off.
The balance control on the amplifier is out of adjustment
Tone is distorted:
The level on the mixer is incorrectly set or the connected amplifier is overmodulated
The connected device does not adhere to the required specifications for a cinch connection or does not have the
appropriate connections
The volume on the connected amplifier is too high.
Repairs other than those described above should only be performed by an authorised
specialist.