11. Operation

a) Setting the Operating Mode
The effect light can be controlled with the integrated controller or with an external DMX controller. Additi-
onally, it can be used as a master device with integrated controller to control other connected effect lights
synchronously in master-slave operation, or as slave device via the controller of another effect light.
The settings are made in the menu via the display (4) and the function buttons MENU (7), UP (8), DOWN (9)
and ENTER (10).
• Push the button MENU (7) to enter the main menu.
• Select the desired operating mode with the buttons UP (8) or DOWN (9) and confirm your selection with
the button ENTER (10).
• Push the ENTER button again to get to the option selection.
• Select the desired operating mode with the buttons UP (8) or DOWN (9) and confirm your selection with
the button ENTER (10).
• To go back one level in the menu, push the button MENU (7).
32
DMX starting address: A001 to A512
DMX mode: 2 / 3 / 4 / 6 / 7 / 14 channels
Slave mode: SL01 to SL04
Sound-to-Light mode: S-01 to S-12
Automatic mode: Pr01 to Pr25
Parameter settings for AUtO and SOUn: S001 to S255
Blackout (Standby): no/yes
Display alignment (180° rotation): no/yes
Colour settings dimmer red: r000 to r255
Colour settings dimmer green: g000 to g255
Colour settings dimmer blue: b000 to b255