Technical Data and Measuring Tolerances

Technical Data
Display . . . . . . . . . . . . . . . . . : 4-digit display up to 9999, with a 4-
Maximum measuring rate . . . : 2.5 measurements per second, i.e. 5
Working temperature
(ambient temperature). . . . . . : 0°C to +50°C (32°F to 122°F)
Storage temperature. . . . . . . : -10°C to +60°C (14°F to 140°F, bat-
Relative air humidity . . . . . . . : 0 to 80 %, non-condensing
Temperature for
guaranteed accuracy . . . . . . : +23°C ±5 K
Temperature coefficient . . . . : additionally 0.01% of reading
Battery exchange display . . . : "
Battery type . . . . . . . . . . . . . : NEDA 1604 9V or 6F22 9V (alkaline)
Weight. . . . . . . . . . . . . . . . . . : 210g (with battery)
Dimensions (l X b X h) . . . . . . : 184 x 64 x 30mm (without wires)
Measuring tolerances
Indication of accuracy in ± (% of reading + display error in Kelvin
"K") "K" for Kelvin stands as absolute value of a temperature diffe-
rence or deviation.
Accuracy for the period of one year at a temperature of +23°C ±5K,
at a relative air humidity of less than
80 %, non-condensing. The warm-up time is 1 minute.
34
digit subdisplay, symbol display and
measuring units
measurements in 2 seconds
tery removed)
+0.03°C (resp. 0.01% of reading
+0.06°F) per K in the range of 0°C
to 18°C and from 28°C to 50°C
" less than approx. 7.3V bat-
+ -
tery voltage