► How to configure the device alarms
1.
Tap the touch area
2.
On the right side tap the white arrow to select "2. Protect".
3.
Set the limits for the equipment alarm relevant to your application if the default value of 110% is unsuitable.
The set values can be entered using the ten-key tab. This will appear by tapping the touch area
that shows the rotary knob assignments.
The user also has the possibility of selecting whether an additional acoustic signal will be sounded if an alarm or
user defined event occurs.
► How to configure the alarm sound (also see "„3.4.3. Configuration via MENU")
1.
Tap the touch area
2.
In the menu page, tap "HMI Settings"
3.
In the following menu page, tap "Alarm Sound"
4.
In the settings page select "Sound on " or "Sound off" and confirm with
3.6.2.1
User defined events
The monitoring functions of the device can be configured for user defined events. Default is that this is deactivated
(action = NONE). The following events can be configured independently and can, in each case, trigger the actions
NONE, SIGNAL, WARNING or ALARM.
Event
Meaning
UVD
UnderVoltage Detection
OVD
OverVoltage Detection
UCD
UnderCurrent Detection
OCD
OverCurrent Detection
OPD
OverPower Detection
These events should not be confused with alarms such as OT and OVP which are for device
protection. User defined events can, however, if set to action ALARM, switch off the DC output
and thus protect the load, like a sensitive electronic application.
► How to configure user defined events
1.
Tap the touch area
2.
On the right side tap the white arrows
"4.3 Event P".
3.
Set the monitoring limits with the left hand rotary knob and the triggered action with the right hand knob
relevant to the application (also see „3.6.1. Definition of terms").
4.
Accept the settings with
As soon as an event is set up with an action other than "NONE" and with accepted settings, an incident can occur
whether the DC output is switched on or off. On leaving the pages "User events" or "Settings" an event can be
directly displayed.
User events are an integral part of the actual user profile. Thus, if another user profile, or the
default profile, is selected and used, the events will be either differently or not configured.
The set values can be entered using the ten-key tab. This will appear by tapping the touch area
on the particular page, e.g. "4.1 Event U", showing the rotary knob assignments.
EA Elektro-Automatik GmbH
Page 56
Helmholtzstr. 31-33 • 41747 Viersen
Germany
on the main screen.
on the main screen
Description
Triggers an event if the output voltage falls below the
defined threshold.
Triggers an event if the output voltage reaches the de-
fined threshold.
Triggers an event if the output current falls below the
defined threshold.
Triggers an event if the output current reaches the de-
fined threshold.
Triggers an event if the output power reaches the de-
fined threshold.
on the main screen..
.
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
.
to select "4.1 Event U" or "4.2 Event I" or
www.elektroautomatik.de
ea1974@elektroautomatik.de
Range
0 V...U
Nom
0 V...U
Nom
0 A...I
Nom
0 A...I
Nom
0 W...P
Nom

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis