10 kW / 15 kW
Internal resistance regulation
Adjustment range
Accuracy
(1
Display: Resolution
Display: Accuracy
(2
Analog interface
(3
Set value inputs
Actual value output
Control signals
Status signals
Galvanic isolation to the device
Insulation
(4
Negative terminal to PE
Positive terminal to PE
Miscellaneous
Cooling
Ambient temperature
Storage temperature
Humidity
Standards
Overvoltage category
Protection class
Pollution degree
Operational altitude
Digital interfaces
Featured
Slot (standard version)
Galvanic isolation from device
Terminals
Rear side
Front side
Dimensions
Enclosure (WxHxD)
Total (WxHxD)
Weight
Article number
(5
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value
(2 The display error adds to the error of the related actual value on the DC output
(3 For technical specifications of the analog interface see „3.5.4.3 Analog interface specification" on page 52
(4 All values valid as from 1. July 2014
(5 Article number of the standard version, devices with options will have a different number
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
PSI 9360-80
PSI 9500-60
0...135 Ω
0...250 Ω
≤ 2% of max. resistance ± 0.3% of maximum current
See section „1.9.6.4. Resolution of the displayed values"
≤ 0.4%
≤ 0.4%
U, I, P
U, I, P
U, I
U, I
DC on/off,
DC on/off,
Remote on/off
Remote on/off
CV, OVP, OT
CV, OVP, OT
Max. 1500 V
Max. 1500 V
DC
DC
Allowed float (potential shift) on the DC output:
Max. ±400 V DC
±725 V DC
Max. +600 V DC
+1000 V DC
Temperature controlled fans, front inlet, rear exhaust
0..50°C
-20...70°C
< 80%, not condensing
EN 61010, EN 61326
EMC TÜV approved acc. IEC 61000-6-2:2005 and IEC 61000-6-3:2006 Class B
2
1
2
< 2000 m
1x USB-B for communication, 1x USB-A for functions, 1x GPIB (optional)
optional: CANopen, Profibus, Profinet, RS232, Devicenet, Ethernet, ModBus
Max. 1500 V DC
Share Bus, DC output, AC input, remote sensing, analog interface, USB-B, master-
slave bus, AnyBus module slot
USB-A
19" x 3U x 609 mm
483 x 133 x 714 mm
~ 24 kg
~ 24 kg
06230359
06230360
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
PSI 9000 3U Series
Model 3U
PSI 9750-40
PSI 91000-30
0...562 Ω
0...1000 Ω
≤ 0.4%
≤ 0.4%
U, I, P
U, I, P
U, I
U, I
DC on/off,
DC on/off,
Remote on/off
Remote on/off
CV, OVP, OT
CV, OVP, OT
Max. 1500 V
Max. 1500 V
DC
DC
±725 V DC
±725 V DC
+1000 V DC
+1000 V DC
~ 24 kg
~ 24 kg
06230361
06230362
www.elektroautomatik.de
ea1974@elektroautomatik.de
PSI 9080-510
0...5 Ω
≤ 0.4%
U, I, P
U, I
DC on/off,
Remote on/off
CV, OVP, OT
Max. 1500 V
DC
±400 V DC
±400 V DC
~ 30 kg
06230364