PSI 9000 3U Series
15 kW
AC Input
Input voltage
Input connection
Input frequency
Input fuse (internal)
Leak current
Power factor
DC Output
Max. output voltage U
Max
Max. output current I
Max
Max. output power P
Max
Overvoltage protection range
Overcurrent protection range
Overpower protection range
Temperature coefficient for set
values Δ/K
Voltage regulation
Adjustment range
Accuracy
(at 23 ± 5°C)
(1
Line regulation at ±10% ΔU
Load regulation at 0...100% load
Rise time 10...90% ΔU
Display: Resolution
Display: Accuracy
(4
Ripple
(2
Remote sensing compensation
Fall time at no load after switching
DC output off
Current regulation
Adjustment range
Accuracy
(at 23 ± 5°C)
(1
Line regulation at ±10% ΔU
Load regulation at 0...100% ΔU
Ripple
(2
Display: Resolution
Display: Accuracy
(4
Compensation 10%->90% load
Power regulation
Adjustment range
Accuracy
(at 23 ± 5°C)
(1
Line regulation at ±10% ΔU
Load reg. at 10-90% ΔU
OUT
Display: Resolution
Display: Accuracy
(4
Efficiency
(3
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error adds to the error of the related actual value on the DC output.
EA Elektro-Automatik GmbH
Page 16
Helmholtzstr. 31-33 • 41747 Viersen
Germany
PSI 9200-210
PSI 9360-120
340...460 V AC 340...460 V AC 340...460 V AC 340...460 V AC 340...460 V AC
3ph,PE
3ph,PE
50/60 Hz
50/60 Hz
6x T16 A
6x T16 A
< 3.5 mA
< 3.5 mA
> 0.99
> 0.99
200 V
360 V
210 A
120 A
15 kW
15 kW
0...220 V
0...396 V
0...231 A
0...132 A
0...16.50 kW
0...16.50 kW
Voltage / current: 100 ppm
0...200 V
0...360 V
< 0.1% U
< 0.1% U
Max
< 0.02% U
< 0.02% U
AC
Max
< 0.05% U
< 0.05% U
Max
Max. 15 ms
Max. 15 ms
See section „1.9.6.4. Resolution of the displayed values"
≤ 0.2% U
≤ 0.2% U
Max
< 300 mV
< 320 mV
PP
< 40 mV
< 55 mV
RMS
Max. 5% U
Max. 5% U
Max
Down from 100% to <60 V: less than 10 s
0...210 A
0...120 A
< 0.2% I
< 0.2% I
Max
< 0.05% I
< 0.05% I
AC
Max
< 0.15% I
< 0.15% I
OUT
Max
< 66 mA
< 50 mA
RMS
See section „1.9.6.4. Resolution of the displayed values"
≤ 0.2% I
≤ 0.2% I
Max
< 2 ms
< 2 ms
0...15.00 kW
0...15.00 kW
< 1% P
< 1.2% P
Max
< 0.05% P
< 0.05% P
AC
Max
* ΔI
< 0.75% P
< 0.75% P
OUT
Max
See section „1.9.6.4. Resolution of the displayed values"
≤ 0.8% P
≤ 0.85% P
Max
~ 95%
~ 94%
Model 3U
PSI 9500-90
PSI 9750-60
3ph,PE
3ph,PE
50/60 Hz
50/60 Hz
6x T16 A
6x T16 A
< 3.5 mA
< 3.5 mA
> 0.99
> 0.99
500 V
750 V
90 A
60 A
15 kW
15 kW
0...550 V
0...825 V
0...99 A
0...66 A
0...16.50 kW
0...16.50 kW
0...500 V
0...750 V
< 0.1% U
< 0.1% U
Max
Max
< 0.02% U
< 0.02% U
Max
Max
< 0.05% U
< 0.05% U
Max
Max
Max. 15 ms
Max. 15 ms
≤ 0.2% U
≤ 0.2% U
Max
Max
< 350 mV
< 800 mV
PP
PP
< 70 mV
< 200 mV
RMS
RMS
Max. 5% U
Max. 5% U
Max
Max
0...90 A
0...60 A
< 0.2% I
< 0.2% I
Max
Max
< 0.05% I
< 0.05% I
Max
Max
< 0.15% I
< 0.15% I
Max
Max
< 48 mA
< 48 mA
RMS
RMS
≤ 0.2% I
≤ 0.2% I
Max
Max
< 2 ms
< 2 ms
0...15.00 kW
0...15.00 kW
< 1.2% P
< 1.2% P
Max
Max
< 0.05% P
< 0.05% P
Max
Max
< 0.75% P
< 0.75% P
Max
Max
≤ 0.85% P
≤ 0.85% P
Max
Max
~ 95%
~ 94%
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
PSI 91500-30
3ph,PE
50/60 Hz
6x T16 A
< 3.5 mA
> 0.99
1500 V
30 A
15 kW
0...1650 V
0...33 A
0...16.50 kW
0...1500 V
< 0.1% U
Max
Max
< 0.02% U
Max
Max
< 0.05% U
Max
Max
Max. 15 ms
≤ 0.2% U
Max
Max
< 2400 mV
PP
PP
< 400 mV
RMS
RMS
Max. 5% U
Max
Max
0...30 A
< 0.2% I
Max
Max
< 0.05% I
Max
Max
< 0.15% I
Max
Max
< 26 mA
RMS
RMS
≤ 0.2% I
Max
Max
< 2 ms
0...15.00 kW
< 1.2% P
Max
Max
< 0.05% P
Max
Max
< 0.75% P
Max
Max
≤ 0.85% P
Max
Max
~ 95%
www.elektroautomatik.de
ea1974@elektroautomatik.de