PSI 9000 3U Series
1.9.6.4
Resolution of the displayed values
In the display, set values can be adjusted in fixed increments. The number of decimal places depends on the device
model. The values have 3 to 5 digits. Actual and set values always have the same number of digits.
Adjustment resolution and number of digits of set values in the display:
Voltage,
OVP, UVD, OVD,
U-min, U-max
Min.
Nominal
Incre-
ment
40 V / 80 V
4
0.01 V
200 V
5
0.01 V
360 V / 500 V 4
0.1 V
750 V
4
0.1 V
1000 V
5
0.1 V
1500 V
5
0.1 V
In manual operation every set value can be set in the increments given above. In this case
the actual output values set by the device will lie within percentage tolerances as shown in the
technical data sheets. These will influence the actual values.
1.9.6.5
USB port (front side)
The frontal USB port, located to the right of the rotary knobs, is intended for the connection of standard USB flash
drives (flash drive). This can be used for:
• Loading or saving sequences for the arbitrary and loading tables for the UI-IU function generator
• Updating HMI firmware (new languages, functions)
USB flash drives must be FAT32 formatted and have a maximum capacity of 32GB. All supported files must
be held in a designated folder in the root path of the USB drive in order to be found. This folder must be named
HMI_FILES, such that a PC would recognise the path G:\HMI_FILES if the drive were to be assigned the letter
G. The control panel of the device can read the following file types from a flash drive:
*.bin
(folder with two files)
wave_u<arbitrary_text>.csv
wave_i<arbitrary_text>.csv
iu<arbitrary_text>.csv
ui<arbitrary_text>.csv
pv<arbitrary>.csv
fc<arbitrary>.csv
EA Elektro-Automatik GmbH
Page 26
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Current,
OCP, UCD, OCD,
I-min, I-max
Min.
Nominal
Incre-
ment
20 A / 30 A
4
0.01 A
40 A / 60 A
4
0.01 A
70 A / 80 A
4
0.01 A
90 A
4
0.01 A
120 A / 140 A 4
0.1 A
170 A / 210 A 4
0.1 A
340 A
4
0.1 A
510 A
4
0.1 A
Firmware updates only for the control panel. The file name format is given like
96230058_FW-BE1_V204.bin, listed in short form as FW-BE1_V204.bin. Other
files won't be recognised or listed.
Function generator for an arbitrary function on voltage (U) or current (I)
The name must begin with wave_u / wave_i, the rest is user defined.
IU table for the XY function generator.
The name must begin with iu, the rest can be user defined.
UI table for the XY function generator.
The name must begin with ui, the rest can be user defined.
PV (photovoltaics) table for XY the function generator.
The name must begin with pv, the rest can be user defined.
FC (fuel cell) table for the XY function generator.
The name must begin with fc, the rest can be user defined.
Power,
OPP, OPD,
P-max
Min.
Nominal
Incre-
ment
3.3 kW
3
0.01 kW
5 kW
3
0.01 kW
6.6 kW
3
0.01 kW
10 kW
4
0.01 kW
15 kW
4
0.01 kW
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
Resistance,
R-max
Min. In-
Nominal
crement
2 Ω / 3,5 Ω
4 0.001 Ω
5 Ω / 7 Ω
4 0.001 Ω
14 Ω / 28 Ω
5 0.001 Ω
42 Ω / 85 Ω
4 0.01 Ω
90 Ω
4 0.01 Ω
135 Ω / 166 Ω
5 0.01 Ω
250 Ω / 270 Ω
5 0.01 Ω
375 Ω / 500 Ω
4 0.1 Ω
562 Ω
4 0.1 Ω
1000 Ω / 1125 Ω 5 0.1 Ω
1500 Ω
5 0.1 Ω