Configuring »Dynamic Ports«
The DVICenter DP32 provides 32 Dynamic Ports. The ports are used to connect the
user modules and the target modules.
In the default setting, the ports 1 to 8 are preconfigured for connecting the user mod-
ules. The ports 9 to 32, however, are preconfigured for connecting the target mod-
ules. You can change the preset configuration in the Config Panel web application.
This paragraph describes the required steps for changing the configuration of the
Dynamic Ports.
NOTE:
The separate manual for the web application describes the operation and
configuration of the Config Panel web application.

Connecting computers to the central module

Accessing the web application requires a network connection between a computer
and the central module.
The following table lists the default settings for the Network A port of the central
module:
IP assignment:
IP address:
Subnet mask:
Conenction type:
NOTE:
The Network B port is disabled in the default.
How to establish a network connection to the central module:
1. Use a category 5e twisted pair cable to connect the network port of any computer
to the Network A port of the central module.
2. Turn the central module and the computer on.
3. Ensure that the IP address of the computer's network port belongs to the subnet
the IP address of the central module belongs to.
NOTE:
Use the IP address 192.168.0.100, for example.