13
Assembly / disassembly
of spare parts
19
18
13.1
Valve disassembly (removing
actuator from body)
1. Move actuator A to the open position.
2. Remove actuator A from valve body 1.
3. Move actuator A to the closed position.
Important:
After disassembly, clean all parts
of contamination (do not damage
parts). Check parts for potential
damage, replace if necessary (only
use genuine parts from GEMÜ).
613, 618
13.2

Removing the diaphragm

Important:
Before removing the diaphragm,
please remove the actuator, see
"Valve disassembly (removing
actuator from body)".
1. Unscrew the diaphragm or pull it out
(diaphragm size 8).
2. Clean all parts of the remains of product
A
and contamination. Do not scratch or
damage parts during cleaning!
3. Check all parts for potential damage.
4. Replace damaged parts (only use
2
genuine parts from GEMÜ).
3
13.3

Mounting the diaphragm

13.3.1 General information

4
Important:
5
Mount the correct diaphragm
1
that suits the valve (suitable for
medium, medium concentration,
temperature and pressure). The
diaphragm is a wearing part.
Check the technical condition and
function of the diaphragm valve
before commissioning and during
the whole term of use. Carry out
checks regularly and determine the
check intervals in accordance with
the conditions of use and / or the
regulatory codes and provisions
applicable for this application.
50 / 64