Herunterladen Inhalt Inhalt Diese Seite drucken

Measurement Tolerances - VOLTCRAFT VC1008 Anleitung

Vorschau ausblenden Andere Handbücher für VC1008:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Measurement tolerances

Accuracy is given as ± (% of reading (= reading = rdg) + display error in digits (= dgt = no. of the smallest
places)). The accuracy is guaranteed for one year at a temperature of +23°C ± 5°C and a relative
humidity of less than 75% (noncondensing).
Measuring
Range
range
400mV
4 V
DC / V
40 V
400 V
1000 V
Overload protection: 1000 V; input resistance: 400 mV = 2.5 GΩ / 4–1000 V = 10 MΩ
4 V
AC / V
40 V
400 V
750 V
Overload protection: 1000 V; input resistance: 10 MΩ
Accuracy AC True RMS: 10%–100% of measuring range
Accuracy AC+DC True RMS: additional + (1% + 30 dgt)
Crest factor: max. 3
In event of short-circuited test leads: display max. 70 dgt.
58
Frequency
±(0.025%+10dgt)
±(0.08%+10dgt)
±(0.08%+10dgt)
±(0.1%+10dgt)
±(0.1%+10dgt)
45Hz~1kHz
±(0.5%+40dgt)
1kHz~10kHz
±(2%+40dgt)
10kHz~120kHz
±(6%+40dgt) (10 - 15% of MR)
±(3%+40dgt) (15 - 100% v. MR)
120kHz~250kHz ±(10%+40dgt) (10 - 30% v. MR)
±(7%+50dgt) (30 - 100% v. MR)
250kHz~400kHz ±(15%+40dgt) (10 - 30% v. MR)
±(12+50dgt) (30 - 100% v. MR)
45Hz~1kHz
±(0.5%+40dgt)
1kHz~10kHz
±(2%+40dgt)
10kHz~20kHz
±(7%+40dgt)
20kHz~100kHz
±(8%+40dgt)
100kHz~400kHz Nicht spezifiziert
45Hz~1kHz
±(0.5%+40dgt)
1kHz~10kHz
±(6%+40dgt)
10kHz~250kHz
Not specified
45Hz~1kHz
±(2%+40dgt)
1kHz~5kHz
±(6%+40dgt)
5kHz~10kHz
±(12%+40dgt)
Accuracy
40.000
Resolution
4.000
at 40.000
± (0.1%+5dgt)
0.01 mV
± (0.2%+5dgt)
0.0001 V
± (0.2%+5dgt)
0.001 V
± (0.3%+5dgt)
0.01 V
± (0.3%+5dgt)
± (0.5%+10dgt)
±(1.5%+10dgt)
±(4%+8dgt)
0.0001 V
±(5%+10dgt)
±(12%+20dgt)
0.001 V
Not specified
0.01 V
Not specified
0.1 V
0.1 V

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis