Herunterladen Inhalt Inhalt Diese Seite drucken

B) Ac Voltage Measurement; Resistance Measurement - VOLTCRAFT VC1008 Anleitung

Vorschau ausblenden Andere Handbücher für VC1008:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

b) AC voltage measurement

(True-RMS)
Never exceed the max. allowable input values, even when measuring superimposed
DC voltages (e.g., ripple voltages). Max. 750 VACrms. Do not touch circuits or parts of
circuits if there could be voltages higher than 25 VACrms or 35 VDC in them.
Proceed as follows to measure AC voltages:
°C
10 A MAX
HzV
µAmA
COM
G
~
The AC voltage measuring range "V AC" exhibits an input resistance of approx. 10 MΩ.
Press the yellow "AC+DC" push button to switch to coupled AC and DC true RMS measurement. "AC+DC
True RMS" appears on the display (1).
c) Resistance measurement
Make sure that all circuit parts, circuits, and components as well as other objects to be
measured are deenergized at all times.
Proceed as follows to measure resistance and for the acoustic continuity test:
°C
10 A MAX
HzV
µAmA% COM
Note!
When performing a resistance measurement, ensure that the measurement points that you touch the
probe tips to for making the measurement are free of dirt, oil, solder paint, and similar contaminants. An
incorrect measurement may result under such circumstances.
If "OL" (for overload) appears on the display, your measurement is above the measuring range
or the measurement circuit is broken.
Connect the black test lead to the COM jack and the red test lead to the
VΩ jack so that they are lying flat on the measuring device.
Set the range selector switch (5) to "V~" (for VC940: "V
For the VC940, switch to AC voltage measurement by pressing the blue
button. "AC True RMS" appears on the display.
Now connect the two probe tips to the measurement object (generator,
circuit, etc.).
The measured value is shown on the main display (12). The frequency
of the AC voltage is shown on the right subdisplay. The active measuring
range is shown on the left subdisplay.
Connect the black test lead to the COM jack and the red test lead to the
VΩ jack so that they are lying flat on the measuring device.
Set the range selector switch (5) to "Ω
Check the continuity of the test leads by touching the probe tips together.
This should produce a resistance of approx. 0 Ω.
Now connect the probe tips to the measurement object. The measured
value is shown on the main display (12) if the measurement object does
not have a high resistance or a broken circuit. The active measuring range
is shown on the left subdisplay.
").
".
47

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis