Programming
B. Programming Abnormal, pen -
following steps and Figure 4-7 guide the user in
programming Abnormal, pen:
1. From the Pens Menu, use the Up (↑) or Down
(↓) Arrow Keys, on the Button Bar, to highlight
"Abnormal, pen" and press the ENTER Button.
2. A menu box will appear with "abnorm, pen high"
and "abnorm, pen low" as the choices. Use the Up
(↑) or Down (↓) Arrow Keys, on the Button Bar, to
highlight your choice of abnormal pen chart
placement, either high or low, and press the
ENTER Button.
3. You have now programmed the pens to go high
or low when the pen goes into an abnormal condi-
tion. Press EXIT as needed to return to the
Charts/Pens Menu.

4.5.5 Direction -

the pen traces to the horizontal or vertical direction
for the Trend View. The trace direction may be
changed at any time without affecting the recording
or brows buffer.
A. Direction Programming -
ing steps and Figure 4-7 to change the pens trace
direction:
1. From the Chart/Pens Menu, use the Up (↑) or
Down (↓) Arrow Keys, on the Button Bar, to scroll
to "Direction" and press the ENTER Button.
2. Use the Up (↑) or Down (↓) Arrow Keys, on the
Button Bar, to scroll and highlight the desired pen
trace direction, either "vertical" or "horizontal" and
press the ENTER Button.
3. After the ENTER button is pressed, use the
EXIT button as needed to return to the Display
Screen.
4-18
Direction allows you to flip
Use the follow-
The

4.6 Points

4.6.1 General.

allows the user to program parameters directly af-
fecting Points. The Points are the actual Channels
in the recorder and may be real live inputs, condi-
tioned live inputs (scaled or adjusted) or computa-
tional channels, for a total of 12 points or channels.
The points are labeled 1 through 9 and A, B, C. The
menu options are as follows:
Constants
• Define constant
Program point
• Point #
• Setup point #
• Copy point #
• Restore point #
• Modify point #
• Delete point #
• Setup, Copy, Restore, and Modify all lead to
the Point Type menu as follows:
¾
Linear type
¾
Industrial square root type
¾
Log linear type
¾
Thermocouple type
¾
RTD type
¾
Calculated type
¾
Conditional type
¾
External type
Additional menus and menu items are con-
tained under each Point Type menu item.