E. Chart speed -
between High and Lo chart speed. The actual chart
speed is changed in the PROGram - Chart/Pens -
Speed menu. The default setting for both high and
low chart speed settings is 60 inches per hour.
When the chart speed is modified, the new speed
and the time is printed on the left side of the
screen. To select the chart speed, use the following
instructions and Figure 3-36:
0 4 /1 6 /9 7
0 4 /1 6 /9 7
0 4 /1 6 /9 7
1 0 3 7 2 6 M A
Figure 3-36 Select Chart Speed Flow Chart
1. Press the FUNCTION Key at the "COMMAND"
prompt and use the UP (↑) or DOWN (↓) Arrow
Keys to highlight "Chart speed".
2. Press ENTER and use the UP (↑) or DOWN
(↓) Arrow Keys to highlight "Speed = HI" or
"Speed = LO".
3. When the display is highlighting correct Hi or
Low speed, press ENTER to activate and EXIT to
return to the "FUNCtion" menu.
Siemens AG C79000-G7374-C211-01
SIREC D Manual
This menu item selects
4 :5 9:2 9
4:5 9 :2 9
4 :5 9:2 9
F. Record Speed -
between High and Lo sample rates for record
speed. The sample rates are set in the PROG –
Record Setup - Sample Rate menu (Chapter 4).
These rates can also be changed via an external
event (Chapter 4). To change record speed,
perform the instructions as follows and refer to
Figure 3-37:
1. Press the FUNCTION Key at the "COMMAND"
prompt and use the UP (↑) or DOWN (↓) Arrow
Keys to highlight "Record speed".
2. Press ENTER and use the UP (↑) or DOWN
(↓) Arrow Keys to highlight "Speed = HI" or
"Speed = LO".
3. When the display is showing the correct hi or
low speed, press ENTER to activate and EXIT to
return to the "FUNCtion" menu.
0 4 /1 6 /9 7
0 4 /1 6 /9 7
0 4 /1 6 /9 7
1 0 3 7 2 7 M A
Figure 3-37 Record Speed Select Flow Chart
Operation