3. Trigger - Selecting Trigger will arm the unit to
record when an external or internal event takes
place. Internal Record-On-Alarm Triggers are set
in the Record Setup menu while External Event
Triggers are set in the Digital Input/Output Setup
menu under the PROGram Button. If the Re-
corder is set in the record TRIGGER mode, ei-
ther of these event triggers will control the Rec-
ord ON or Record OFF function depending on
whether the events are active or inactive. To set
the Record Mode to Trigger, perform the follow-
ing steps and refer to Figure 3-32:
a. Use the UP (↑) or DOWN (↓) Arrow Keys to
highlight "Record On/Off" and press ENTER.
b. Use the UP (↑) or DOWN (↓) Arrow Keys to
highlight "Trigger" and then press ENTER.
c. A pop up window will ask to confirm the se-
lection "trigger on?". Press "YES" to accept the
Trigger ON state or "No" to exit without turning
the trigger mode ON.
BR O W S
V IE W
0 4 /1 6 /9 7
D ISP
0 4 /1 6 /9 7
E N T E R
0 4 /1 6 /9 7
E N T E R
0 4 /1 6 /9 7
trigger on?
E N TER
YES
N O
E N T E R
0 4 /1 6 /9 7
1 0 3 7 2 2 M A
Figure 3-32 Turn Trigger Mode to ON Flow
Chart
NOTE
Triggered recordings can only be made if
the disk record mode is set to Fill-To-End.
See Chapter 4. Cyclic files cannot be trig-
gered.
Siemens AG C79000-G7374-C211-01
SIREC D Manual
J O G
M E N U
4 :5 9 :2 9
P R O G
F U N C
E XIT
4 :59 :2 9
EX IT
4 :5 9 :2 9
EX IT
4 :5 9 :2 9
EXIT
4 :5 9 :2 9
EX IT
NOTE
Trigger Mode can be invoked with the Re-
corder in the Record ON or OFF Mode.
With the Trigger Mode turned ON, the cur-
rent record status is shown in the Disk Info
Window in the top right corner of the
screen. If the unit is not recording, this win-
dow will show REC TRIG. To start record-
ing, without waiting for a trigger, turn Rec-
ord ON as detailed in paragraph 3.4.4.A.2.
B. Activate Point -
temporarily bypassed point or points to the
measurement cycle for measuring inputs and
displaying information. To activate a point perform
the following steps and use the flow chart shown in
Figure 3-33:
1. Press the FUNC Key on the Main Menu Bar.
2. Use the UP (↑) or DOWN (↓) Arrow Keys to
highlight "Activate pt" and press ENTER.
3. Use the pup-up numeric keypad to enter the
point number to activate and press ENTER on
the Menu Bar.
4. The display then scrolls to the next point.
When point activation is finished, press EXIT in
the pop-up keypad and the display will return to
the "Activate pt" display.
B R O W S
V IE W
0 4 /1 6 /9 7
D IS P
0 4 /1 6 /9 7
E N T E R
0 4 /1 6 /9 7
E N TE R
0 4 /1 6 /9 7
1 0 3 7 2 3 M A
Figure 3-33 Activate Point Flow Chart
Operation
This menu item returns a
J O G
M E N U
4 :5 9 :2 9
P R O G
F U N C
E X IT
4:5 9 :2 9
E X IT
4 :5 9 :2 9
P oint? 1
A
7
8
B
4
5
C
3
2
4 :5 9:2 9
E X IT
E X IT
3-17
9
6
1

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis