Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.2 Set-up

The grease separator is delivered ready for operation. The
grease separator is easy to transport and fits through any
standard door. The system is then set up as follows.
Grease Separator basic version :
1. Set up the grease separator and make sure it is horizon-
tal.
2. Grease the cover seal and insert it into the cover groove.
Fit the cover and fix in place with the aid of the clamping
ring.
3. Connect the inlet and outlet of the grease separator sys-
tem. Check the connection pipes for leaks after the sys-
tem has been put into operation. If water is leaking out,
check the fit of the clamping muffs.
Grease Separator direct disposal:
1. Set up the grease separator and make sure it is horizon-
tal.
2. Grease the cover seals and insert them into the cover
groove. Fit the covers and fix in place with the aid of the
clamping rings.
3. Connect the inlet and outlet of the grease separator sys-
tem. Check the connection pipes for leaks after the sys-
tem has been put into operation.
If water is leaking out, check the fit of the clamping
muff(s) and tighten the screw connections if necessary.
4. The riser pipe is fitted to the grease separator ready for
operation (it can be removed if necessary. To do this,
remove the spring clips on the pipe clamps. The riser
pipe can now be removed from the grease separator.
When the riser pipe is replaced, make sure the seal for
the pipe duct in the base area of the separator is cor-
rectly in place. The seal and the pipe should be well
lubricated for installation.).
Connect the disposal flange on the disposal pipe routed
on site. (Flange connection DN 65, PN 10, DIN 2501,
hole pattern 145 mm). At the end of the disposal pipe,
the Storz-B coupling (R 2 1/2" inner thread) must be
mounted in a spot easily accessible for the disposal
vehicle. Any compensators necessary to prevent sound
transmission must be inserted in the disposal pipe.
Grease Separator D + S
1. Set up the grease separator and make sure it is horizon-
tal.
2. Grease the cover seals and insert them into the cover
groove. Fit the covers and fix in place with the aid of the
clamping rings.
3. Connect the inlet and outlet of the grease separator sys-
tem. Check the connection pipes for leaks after the sys-
tem has been put into operation. If water is leaking out,
check the fit of the clamping muff(s) and tighten the
screw connections if necessary.
4. The riser pipe is fitted to the grease separator ready for
operation. (It can be removed if necessary. To do this,
remove the spring clips on the pipe clamps. The riser
pipe can now be removed from the grease separator.
3. Installation
When the riser pipe is replaced, make sure the seal for
the pipe duct in the base area of the separator is cor-
rectly in place. The seal and the pipe should be well
lubricated for installation.)
4. Connect the disposal flange on the disposal pipe routed
on site. (Flange connection DN 65, PN 10, DIN 2501,
hole pattern 145 mm) At the end of the disposal pipe,
the Storz-B coupling (R 2 1/2" inner thread) must be
mounted in a spot easily accessible for the disposal
vehicle. Any compensators necessary to prevent sound
transmission must be inserted in the disposal pipe.
5. The pump must be attached to the floor using the
screws provided. The rubber mat provided must be pla-
ced under the bracket console as sound insulation.
6. The pump´s outlet should be connected to the disposal
pipe using a rubber coupling with twin steel fastening
clamps. Clamps should be tightened to a torque of 10 Nm.
7. DIN 1988, DVGW work sheet and local requirements of
the authorities must be heeded when connecting the fil-
Connection with KESSEL filling device (included):
ling and rinsing pipes.
- Fix the filling device in the filling and rinsing connection
screws and using pipe brackets.
- Bring the filling and rinsing pipes together and connect them
Connection with other separator systems
together to the R1 inner thread of the filling device.
- Connect the filling and rinsing device to the filling and rinsing
connection (R 1 1/2 inner thread).
8. Electrical installation
Electrical work may only be carried out by professional
electricians.
A 16 A assembly socket in CEE form must be installed on
site. Fuse T 16 A.
Connect the pump. Check the phase sequence of the elect-
rical installation.
9. Power plug with integrated motor protection switch 16 A
CEE Motor protection plug with motor protection switch
setting range 4 - 6.3 A => Current value must be set to the
nominal pump current (5.6 A) using the setting wheel
Switch-on and switch-off are carried out manually using the
motor protection switch => black and red button
-> With phase sequence control
-> With thermal contact monitoring => for thermal monitoring
of the pump.
-> With undervoltage trigger => is switched off automatically
when voltage drops below minimum or there is a power
failure
10. Dimensions: Length 270 mm, width 110 mm, depth 100
mm, Weight: approx. 2000 g
11. Pump system with chopper
-> - Fuse: for 3,0 kW pump – 16 AMP
--> For the contents of grease separators in homes and gas-
tronomy
12. Operating instructions must be displayed near the separa-
tor.
23

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Euro dEuro d+s

Inhaltsverzeichnis