NOTE:
A combustion air intake pipe is required.
A minimum length is not required.
NOTE:
The combustion air intake pipe with combustion air intake si-
lencer must not exceed a max. length of 2.0 m.
NOTE:
The maximum total combined length of the combustion air
intake pipe and the exhaust pipe must not exceed:
With exhaust silencer: 2.0 m
Without exhaust silencer: 5.0 m
See also Chapter 8, "Exhaust system".
< 2.0 m
Fig. 19
Max. 2 m length of combustion air intake pipe with
combustion air intake silencer
7.2.
Notes on the combustion air intake pipe
Characteristics of the combustion air intake pipe
IMPORTANT
Risk of confusing the exhaust pipe with the combustion
air pipe!
Damage to the combustion air pump cable
Attach the exhaust pipe only to the exhaust connection
piece
Combustion air intake pipe
Inner diameter
Minimum bending radius
Max. sum of all bends
Combustion air inlet
The air for the combustion chamber of the heater must not
be drawn from the passenger compartment of the vehicle.
(Requirement from ECE-R 122, Point 5.3.5.1.).
The combustion air should only be drawn from areas in which no persons
are present.
The combustion air should only be extracted from a cool area which is
protected from splashing water.
The pipe opening should be positioned so as to prevent the penetration
of water if the vehicle is driven through water.
Combustion air
Value
25 mm
50 mm
270°
71