3. Check of inflation device before use
4. Check of life jackets before
(quick check)
each season / extended cruises
Each time before you put on the life jacket, check the opera-
Open the press studs, Velcro fasteners or zippers of the life
tional readiness of the inflation device(s). To that end, open
jacket and unfold the buoyancy chamber.
the life jacket at the Velcro fastener or zipper and / or check
the inflation device through the inspection window.
Inflate the buoyancy chamber via the oral valve fully (also
refer to Chapter 6) and allow it to rest for approx. 16 hours.
1 Gas cartridge (CO
) full?
If the buoyancy chamber is still full after this time, it is ok.
2
Unscrew the cartridge and check it is unmarked (see Fi-
If your life jacket is provided with a second buoyancy cham-
gure 1). If the mouth is damaged, replace the gas cartridge
ber (e.g. SOLAS jackets), repeat this and the following steps
with a new original SECUMAR spare cartridge. Screw the
for the second chamber.
cartridge in again until the inspection window shows fully
green, then do not turn it any further.
• Oral valve functioning?
Remove the dust cap and check the valve insert for opera-
2 All indicators green?
tional readiness using inverted dust cap or the nose of the
SECUMATIC 3001S (see Figure 2)
dust cap see Figure 4. After pressing down the oral valve
A = manual release lever secured?
with the dust cap and withdrawing it, the valve must close
B = Automatic tablet present?
completely. Install the dust cap again.
C = Cartridge screwed in correctly?
• Protection cover and straps undamaged?
DE
SECUMAR 301SM (see Figure 3)
Check the protection cover, webbing and fittings for da-
A = manual release lever secured?
mage and the existing accessories for completeness. If the
GB
B = Cartridge screwed in correctly?
CLICK buckle does not close smoothly, apply some Teflon
spray to make it operational again.
FR
If all indicators are green and the cartridge is full, the infla-
Taking the life jacket out of service may be necessary, for
tion device is operational, otherwise it must be made ready
example, if the strength of the fabric and the straps is redu-
NL
as described in Chapter 8.
ced by prolonged UV impact. This applies in particular to
life jackets with an integrated harness!
DK
Repeat this inspection with the second inflation device of
Life jackets with integrated harnes must be taken out of ser-
your life jacket, if applicable.
vice (e.g. after a fall or chemical impact).
SE
After checking the inflation device and making it ready
again, if necessary, close the protection cover and make
• Gas cartridge (CO ² ) o.k.?
FI
sure the pull-cord for manual release hangs out freely from
Replace empty and corroded / rusty gas cartridges with
the protection cover.
new original SECUMAR spare cartridges.
ES
Should you find any defects during the inspection, take your
life jacket to the SECUMAR SERVICE for maintenance in any
NO
case (via authorized dealer or directly to manufacturer).
IT
HU
PL
8
5. Putting on the life jacket
Always wear the life jacket on top of your clothing. Open
the buckle and put on the life jacket like a normal jacket
or pull over head in the case of closed models see Figures
6 and 7. Close buckle safely. Also refer to supplementary
operating instructions. Never wear the life jacket unfas-
tened!
Adjust the body belt such that there is approx. 2 cm space
(two fingers) between your body and the belt. Only a tightly
fitting life jacket will keep you in a stable position on your
back.
If applicable, close the crotch strap and adjust it so that it
fits comfortably.
WARNING: Wearing the life jacket loosely or unfastened
is dangerous.
6. Inflating the life jacket
Life jackets with SECUMATIC 3001S automatic inflation
device:
When the user jumps into the water, the life jacket is inflated
fully automatically. Out of the water or if fully automatic
inflation fails, the inflation process can be started by pulling
the pull-cord firmly.
Life jackets with SECUMAR 301SM manual inflation de-
vice: The inflation process is released by pulling the pull-
cord firmly.
Inflating via oral valve (tightness check) / refilling air:
8. Making inflation device ready again
(re-arming)
Open the life jacket manually and blow up the buoy-
ancy chamber via the mouth valve. To that end pull
off the dust cap from the mouth valve. When refilling
After each use involving the inflation of the life jacket, the
air via the mouth valve, avoid breathing in CO ² gas
inflation device must be made ready for use again. To do
from the buoyancy chamber (non-toxic, but may cause
that, you will need an original SECUMAR spares package
coughing or dizziness).
(re-arming kit).
Automatic inflation device SECUMATIC 3001S (see Figure 7)
• Unscrew empty cartridge from inflation device and dis-
7. Handling after use / making jacket
pose of it.
ready for use again
• Fold out side lever until it engages. Warning: High spring
loads!
• Cleaning the life jacket.
• Fold manual release lever into case and secure with new
pin (if necessary).
Allow moist or wet life jacket to dry on a hanger or hang
• Insert new original SECUMAR automatic tablet in tablet
from the neck part. Do not dry on a heating radiator! Re-
compartment. If necessary, blow out any residues of the old
move oil and grease immediately. Clean using a standard
tablet, do not use any tools! For easier insertion, you may
commercial gentle washing detergent or mild soapsuds. Rin-
press the lever a bit up over the attachment point. Warning:
se with clean water in any case. Note the care information
Enclosure and hands must be dry! Never insert any objects
on the life jacket.
other than an original SECUMAR automatic tablet!
Do not use any alcohol or solvent containing cleaning
• Fold down side lever again.
agents!
• Screw new full CO
window C shows fully green, then do not turn it any further.
• Releasing air via the oral valve.
The size required (in g weight) is imprinted on the buoyancy
chamber.
To release the air, remove the oral valve dust protection cap.
If all indicators A, B and C are green, the life jacket is
Press down the valve with the inverted dust cap or with the
operational again.
nose of the dust cap (never use pointed objects). Press out
the air to empty the buoyancy chamber completely. After
Manual inflation device SECUMAR 301SM (see Figure 8)
emptying the buoyancy chamber, reinstall the dust cap see
• Unscrew empty cartridge from inflation device and dis-
Figure 4.
pose of it.
• Fold manual release lever into case and secure with new
clip.
• Screw new full CO
window B shows fully green, then do not turn it any further.
The size required (in g weight) is imprinted on the buoyancy
chamber.
If all indicators A and B are green, the life jacket is opera-
tional again.
9. Replacing the tablet
To replace the tablet (e.g. after use in environments with
high atmospheric moisture), please refer to the instruc-
tions for making the inflation device ready for use again
(Chapter 8).
Please note: Always remove the CO ² cartridge before actu-
ating the tensioning lever.
10. Packing the life jacket
Release all air from the buoyancy chamber (see Chapter 7).
Close the oral valve with the dust cap (see Chapter 4).
Fold up life jacket following the instructions on the supplied
product information. Ensure that the inflation device is not
„wrapped up". The buoyancy chamber must not be twis-
ted. The white retaining straps must not be pulled together!
Close all press studs, Velcro fasteners and zippers carefully.
The manual release pull-cord must hang out of the protec-
tion cover freely and be accessible. The straps must not be
spare cartridge in until the inspection
twisted or knotted.
2
spare cartridge in until the inspection
2
DE
GB
FR
NL
DK
SE
FI
ES
NO
IT
HU
PL
9