ubbink Ubiflux F150+ Bedienungsanleitung Seite 115

Vorschau ausblenden Andere Handbücher für Ubiflux F150+:
Inhaltsverzeichnis

Werbung

12
GB
STEP NO. DESCRIPTION
19
Selection input 2
20
Minimum voltage input 2
21
Maximum voltage input 2
Conditions
22
switching input 2
Supply fan mode
23
switching input 2
Extract fan mode
24
switching input 2
25
Geo heat exchanger
Minimum temperature
geo heat exchanger
26
(Below this temperature
the valve opens.)
Maximum temperature
geo heat exchanger
27
(Above this temperature
the valve opens.)
STEP NO. DESCRIPTION
28
RH-sensor
Sensitivity
29
RH-sensor
112
Instelwaarden/ Setting values/ Einstellwerte
FACTORY SETTING
Ubiflux F150 PLUS
1
0,0 V
10,0 V
0
5
5
OFF
5,0 °C
25,0 °C
FACTORY SETTING
Ubiflux F150
OFF
0
Ubiflux F150(+) - F200(+) - F300(+)
Valeurs de réglage
ADJUSTING RANGE
0 (= normally open contact)
1 (= 0 - 10V input active)
2 (= normally closed contact)
3 (= input 2/ bypas open 12V;
bypass closed 0V)
4 (= input 2/ bypas open 0V;
bypass closed 12V)
0,0 Volt - 10,0 Volt
0,0 Volt- 10,0 Volt
0 (= Off)
1 (= On)
2 (= On if conditions bypass open satisfied)
3 (= Bypass control)
4 (= Bedroom valve)
0 (= Input fan off)
1 (= Absolute min. flow rate 30 m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
7 (= No input fan activation)
0 (= Extract fan off)
1 (= Absolute min. flow rate 50m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
7 (= No extract fan activation)
OFF (= Valve control geo heat
exchanger off)
ON (= Valve control geo heat
exchanger on)
0,0 °C - 10,0 °C
15,0 °C - 40,0 °C
ADJUSTING RANGE
OFF (= RH-sensor not active)
ON (= RH-sensor active)
+2 most sensitive
+1
0 default setting RH-sensor
-1
-2 least sensitive
STEP
0,5 V
0,5 V
/h)
3
/h)
3
0,5 °C
0,5 °C
STEP