english
Supply voltage:
Motor protection:
Degree of protection:
Winding class:
Temperature class:
Ambient temperature:
Media temperature:
Minimum pressure
at 500m altitude:
Pression de service nécessaire: 10 bar
Noise:
Leakage current:
english

10. Specifications

1×230-240 V +6/-10%, 50/60 Hz
No external motor protection is necessary
IP 44
Classe d'isolation F
TF 110
max. 40 °C
+15 °C to 95 °C, for short periods (ca. 30 min) 110 °C
The temperature of the medium must be higher
than the ambient temperature to prevent condensation water
from forming in the terminal box and the stator.
Ambient temperature
°C
15
20
25
30
35
40
for short periods, ca. 30 min
1)
up to 75 °C water temperature
at 90 °C water temperature
at 110 °C water temperature
sound pressure level under 54 dB(A)
The power line filter of the pump causes a leakage current
to the ground wire of less than 3.5 mA during operation.

11. Disposal

This product and the special electronic components (lead-free)
must be disposed of in accordance with the environmental
regulations.

Media temperature
Min. °C
Max. °C
15
85
20
95
25
95
30
95
35
90
40
70
0,10 bar
0,45 bar
1,20 bar
Max. °C
1)
110
110
110
110
100
100