16 Troubleshooting

The following table shows fault symptoms and describes remedial measures in the event of your product failing to work
properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Product does not run.
Product runs, but no pressure.
Product runs, pressure shown
on the manometer, but tools are
not running
Possible cause
Mains voltage not present.
Mains voltage too low.
Outside temperature is too
low.
Motor is overheated.
The safety valve leaks.
The seals are damaged.
The drain screw for conden-
sate leaks.
Hose connections leaking.
Quick-coupler leaking.
Pressure set too low at pres-
sure regulator.
www.scheppach.com
• These statements only apply to devices installed and
sold in the countries of the European Union and which
are subject to the European Directive 2012/19/EU. In
countries outside the European Union, different regu-
lations may apply to the disposal of waste electrical
and electronic equipment.
Remedy
Check cable, mains plug, fuse and socket.
Avoid extension cables that are too long. Use exten-
sion cables with sufficient conductor cross-section.
Do not operate at outside temperatures below +5°C.
Allow the motor to cool down. If necessary, remedy the
cause of the overheating.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Check the seals and have any damaged seals re-
placed by a service centre.
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
Check compressed air hose and tools, replace if nec-
essary.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Turn up the pressure regulator further.