Herunterladen Diese Seite drucken

Before Commissioning; Mains Power Connection; Operation; Electrical Connection - Scheppach Hc24X Originalbetriebsanleitung

Vorschau anzeigen Andere Handbücher für HC24x:
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
2. Fit the foot (7) onto the assembly holes provided on
the base frame.
3. Fit the foot (7) to the base frame with a screw (7a) and
secure it with a nut (7b).
Use two 10 mm open-end spanners/socket spanners.
4. Place the product on a level, even surface.
9

Before commissioning

WARNING
Danger of injury!
Do not insert the mains plug into the socket until you
are ready to use the product.
WARNING
Always remove the mains plug before carrying out
adjustments on the product.
CAUTION
Unsuitable extension cables could be dangerous. There
is a risk of persons being injured due to electric shock.
General information
• Proceed with caution. Familiarise yourself with the ap-
plication and possible restrictions, but also with the
specific potential dangers.
• Before connecting of the product, make certain that
the data on the type plate matches with the mains
power data.
• Inadequately informed operators can endanger them-
selves and others through improper use. The operator
is responsible for the safety of third parties.
• Check the product regularly for damage.
• The product must be installed close to the consumer.
• Long air lines and supply cables (extension cable)
should be avoided.
• Ensure that the intake air is dry and dust-free.
• Do not install the product in a damp or wet room.
• Operate the product only in suitable areas (well venti-
lated, ambient temperature +5°C to 40°C). There must
be no dust, acids, vapours, explosive or flammable
gases in the room.
• The product is suitable for use in dry rooms. It must
not be used in areas where splashed water is present.
• The product may only be used outdoor briefly when
the ambient conditions are dry.
• The product must always be kept dry and must not be
left outdoors after work is complete.
9.1

Mains power connection

• The product is equipped with a mains cable with an
earthed plug. This can be connected to any mains
socket 220-240 V~ 50 Hz with an earth contact and
that is protected at 16 A.
• Before commissioning, ensure that the mains voltage
matches with the operating voltage and the machine's
power rating on the type plate.
24 | GB
• Long supply cables, extensions, cable reels, etc.
cause a drop in voltage and can impede motor start-
up.
• At low temperatures below +5 °C, sluggishness may
make starting difficult or impossible.

10 Operation

10.1
On/Off switch (4) (Fig. 5)
1. Insert the mains plug into a properly fused socket.
2. Pull the On/off switch (4) upwards to switch on the
compressor.
3. Press the On/off switch (4) down to switch off.
10.2
Adjusting the pressure (Fig. 6)
1. The pressure at the manometer (3) is adjusted with
the pressure regulator (3a).
The pressure set can be utilised by connecting to the
quick-coupling (2).
2. The vessel pressure can be read off at the pressure
gauge (3a).
The vessel pressure is taken at the quick-coupling (2).
10.3
Fitting the compressed air hose*
(Fig. 6)
Connect the plug nipple* of the compressed air hose* to
the quick coupling (2). Then connect the compressed air
tool* to the quick coupling* of the compressed air hose*.
* = may not be included in the scope of delivery!

11 Electrical connection

The connection complies with the applicable national
provisions.
Connections and repair work on the electrical equipment
may only be carried out by electricians.
• Before commissioning, ensure that the mains voltage
matches with the operating voltage on the type plate.
• Pay attention to the manufacturer's instructions when
using extension cables.
When working with spray attachments and during tempo-
rary use outdoors, the product must be connected to a re-
sidual current circuit breaker with a trigger current of 30
mA or less.
11.1
Damaged electrical connection
cables
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are passed
through windows or doors,
• Kinks where the connection cable has been improper-
ly fastened or routed,
• Places where the connection cables have been cut
due to being driven over,
• Insulation damage due to being ripped out of the wall
socket,
• Cracks due to the insulation ageing.
www.scheppach.com
loading