Defective components must be disposed of as spe-
cial waste. Ask your dealer or your local council.
Old devices must not be disposed of with house-
hold waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical
and electronic equipment (WEEE). This product must
be disposed of at a designated collection point. This
can occur, for example, by handing it in at an author-
ised collecting point for the recycling of waste elec-
trical and electronic equipment. Improper handling
of waste equipment may have negative consequenc-
es for the environment and human health due to po-
tentially hazardous substances that are often con-
tained in electrical and electronic equipment. By
properly disposing of this product, you are also con-
tributing to the effective use of natural resources.
You can obtain information on collection points for
waste equipment from your municipal administration,
public waste disposal authority, an authorised body
for the disposal of waste electrical and electronic
equipment or your waste disposal company.
12. Troubleshooting
Fault
Possible cause
No supply voltage.
Insufficient supply voltage.
The compressor does
not start.
Outside temperature is too low.
Motor is overheated.
The non-return valve leaks.
The compressor starts
The seals are damaged.
but there is no pres-
sure.
The drain plug for condensation water
(1) leaks.
The hose connections have a leak.
The compressor
starts, pressure is
shown on the pressure
A quick-lock coupling has a leak.
gauge, but the tools
do not start.
Insufficient pressure set on the pres-
sure regulator (7).
www.scheppach.com / service@scheppach.com / +(49)-08223-4002-99 / +(49)-08223-4002-58
Remedy
Check the supply voltage, the power plug and the
socket-outlet.
Make sure that the extension cable is not too long.
Use an extension cable with large enough wires.
Never operate with an outside temperature of below
+5° C.
Allow the motor to cool down. If necessary, remedy
the cause of the overheating.
Have a service center replace the non-return valve.
Check the seals and have any damaged seals re-
placed by a service center.
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
Check the compressed air hose and tools and replace
if necessary.
Check the quick-lock coupling and replace if neces-
sary.
Increase the set pressure with the pressure regulator.
GB | 97