DuoPrint

Print Settings

Keys:
,
Speed
Contrast
Key:
Transfer ribbon control
Key:
Y displacement
Key:
X displacement
Key:
Tear off

Label Layout

Keys:
,
,
Label length
Gap length
Key:
Column printing
Key:
Measure label
Key:
Label type
Key:
Material selection
88
Indication of print speed in mm/s (see the technical data).
The print speed can be determined for each print order anew. The setting of print speed
affects also the test prints.
Indication of value to set the print intensity when using different materials, print speeds or
printing contents.
The value can be set for both printheads.
Value range: 10% to 200 %.
Off: The ribbon control is deselected, i.e. the printer continues without an error message.
On: The ribbon control is selected, i.e. the current print order is interrupted and an Error
Message appears at the printer display.
strong sensibility: The printer reacts immediately to the end of the transfer ribbon.
weak sensibility: The printer reacts at approx. 1/3 more slowly to the end of the transfer
ribbon.
Indication of initial point displacement in mm. Displacement of the complete print in paper
direction. With positive values the print in paper direction starts later.
The value is set for both printheads together.
Value range: −30.0 to +90.0.
Displacement of the complete print transverse to the paper direction. The displacement is
possible only up to the edges of the printing zone and is determined by the width of the focal
line in printhead.
The value is set for both printheads together.
Value range: −90.0 to +90.0.
Indication of value to which the last label of a print order is moved forward and is moved
back to the beginning of label at a new print start.
Value range: 0 to 50.0 mm
Standard: 12 mm.
Indication of label length in mm (see the technical data).
Indication of distance between two labels in mm (not for continuous labels).
Minimum value: 1 mm.
Indication of width of one label as well as how many labels are placed side by side.
Press key
to start measuring.
Generally adhesive labels are set. Press key
Selection of the used label and transfer ribbon material.