12
Custom Schedules
To customize the run schedule for your VS2 Variable Speed
Pump, the pump must be stopped. Be sure that the Start/
Stop button LED is not illuminated.
Programming a Custom Schedule:
Note: When programming, the LED light next to the
parameter ("Speed", "Time" and "Duration") you are setting
will blink.
1. Stop the pump if it is running by pressing the Start/
Stop button.
2. Press the "1" button. The LED above the selected SPEED
will begin to blink and the "Speed" parameter LED will
blink while editing. See Figure 9.
3000
Figure 9: Setting Speed
3. Use the "+" and "-" arrows to adjust the speed in RPM
for SPEED 1.
Note: Speed is adjusted up or down by increments of
10 RPM.
4. Press the "1" button again and the display will change
to SPEED 1 start time. The "Time" parameter LED will
begin to blink. See Figure 10.
8 : 00
AM
Figure 10: Setting Start Time
5. Use the "+" and "-" arrows to adjust the daily start time
for SPEED 1.
6. Press the "1" button again and the display will change to
SPEED 1 duration. The "Duration" parameter LED will begin
to blink. See Figure 11.
2 : 00
Figure 11: Setting Duration
7. Use the "+" and "-" arrows to adjust the duration for SPEED
1 in hours and minutes.
Note: The duration parameter is adjusted in 15 minute
increments.
8. Pressing the "1" button will continue to cycle through
these parameters, but the changes are immediately saved
as they are adjusted.
9. Press the "2" button. The LED above SPEED 2 will begin
to flash and the corresponding parameter LED will flash
while editing.
10. Use the "+" and "-" arrows to adjust the speed in RPM
for SPEED 2.
11. Press the "2" button again and the display will change to
SPEED 2 duration.
Note: SPEEDs 2 and 3 do not have a start time, as they
begin their duration immediately after the previous SPEED
finishes.
12. Use the "+" and "-" arrows to adjust the duration for SPEED
2 in hours and minutes.
13. Repeat steps 9-12 to program SPEED 3 and QUICK CLEAN.
Note: Remember that the duration allowed for SPEED 3
will be limited to the remaining time in a 24 hour day. Any
time in the 24 hour day not programmed into SPEEDs 1-3,
the pump will remain in a stationary state.
[ SPEED 1 + SPEED 2 + SPEED 3 < 24 Hours ]
14. Press the Start/Stop button and ensure the LED is lit. The
pump is now on and will run the custom user-programmed
schedule.