Measuring Functions

Standard display screen
a
b
c
v
u
t
s
k
r
q p
o
a Date/time: see "Time/Date", page 28
b Measuring frame: see "Measuring Surface for Surface-tem-
perature Measurements", page 24
c Status indicator:
Measuring tool is ready to measure; press the
measure button 4.
(Continuous) measurement running; lasers are
switched on.
Measurement ended; lasers are switched off;
measuring results are fixed.
d Audio signal switched off indicator (see "Audio Signal",
page 29)
e Zoom level indicator: see "Setting the Zoom Level",
page 23
f Bluetooth® switched on indicator (see "Data Transmission
via Bluetooth®", page 28)
g Battery status indicator: see "Battery Status Indicator",
page 23
h Function indicator/Measured value for relative humidity
i Function indicator/Measured value for ambient tempera-
ture
j Function indicator/Result for dew point temperature
k Minimum/maximum measured value for surface tempera-
ture during a measurement
l Result scale
m Menu symbol
n Surface temperature alarm indicator: see "Surface Tem-
perature Alarm", page 26
o Measured value for surface temperature measurement
p Current mode
q Mark for measured value or result (depending on selected
mode)
r Gallery symbol
s Function indicator/Measured value for average tempera-
ture
t Function indicator/Measured value for contact tempera-
ture
u Emissivity degree indicator
v Memory symbol
Bosch Power Tools
Single Measurement
Briefly press the measure button 4 once to switch on the la-
sers and trigger an individual measurement in the selected
mode. Hold the measuring tool aimed at the measuring object
d e
f g
without moving it until the measured value is displayed. Meas-
urement can take up to 1 second.
The lasers switch off automatically after completion of the
measurement. The measuring results appear on the display.
h
Press the measure button 4 again to start a new measurement
with the set measuring parameters.
i
Continuous Measurement (Tracking)
j
Press and hold the measure button 4 to perform continuous
k
measurements in the selected mode. The lasers remain
l
switched on. Using slow movements, aim the laser points one
after the other at all surfaces whose temperature you want to
measure. Move the measuring tool slowly in the room to per-
n
m
form humidity and ambient temperature measurements.
The indications on the display are continually updated. As
soon as you let go of the measure button 4, the measurement
is interrupted and the lasers are switched off. The last meas-
uring results are fixed on the display.
Press the measure button 4 again to start a new measurement
with the set measuring parameters.
Saving/Displaying/Sending Measuring Results
After completion of a measurement, the memory symbol v ap-
pears on the display to indicate that you can save the measur-
ing results. To do so, press the save/send button 9.
The measuring results are saved as a JPG file (screenshot of
the fixed display).
You can also delete all saved files at once. For this, see "Delete
All Images", page 29.
English | 25
– To display saved screenshots, press the left-
hand function button 17 under the gallery
symbol r. The most recently saved photo ap-
pears on the display.
– Press the right-hand 11 or left-hand 15 arrow
button to switch between the saved screen-
shots.
– To send the displayed measuring result via
Bluetooth®, press the save/send button 9. If
the Bluetooth® connection is not yet switched
on (see "Data Transmission via Bluetooth®",
page 28), it is activated by pressing the
save/send button.
– To delete the displayed screenshot, press the
right-hand function button 10 under the trash
can symbol.
– To confirm the deletion, press the left-hand
function button 17 under the tick symbol.
– To cancel the deletion, press the right-hand
function button 10 under the cross symbol.
– To exit the gallery view and return to the meas-
uring mode, press the left-hand function but-
ton 17 under the back symbol.