electrical protection measures
are in place.
• Never operate the pressure
washer if the power supply
cable or other important parts,
such as the high-pressure hose
or the gun, are damaged.
• Protect the pressure washer
from frost and dry running.
• Use only original accessories
and do not carry out conversion
work on the equipment.
• Please read the notes in the op-
erating instructions on the topic
of "maintenance and cleaning".
Any measures above and be-
yond these, particularly open-
ing the equipment, are to be
carried out by an electrician. In
the case of repairs, always con-
tact our service centre.
• The washer was designed for
operation with a neutral deter-
gent based on a biologically
decomposable anionic tenside.
Other detergents or chemical
substances could impair the
safety of the washer and dam-
age it.
• If you come into contact with
cleaning agents, rinse with
plenty of clean water.
• Water that has passed through
a backflow preventer is classi-
fied as undrinkable.
• High-pressure hoses, fittings
and couplings are important
for machine safety. Use only
high-pressure hoses, fittings and
couplings recommended by the
manufacturer.
• To ensure machine safety, use
only original replacement parts
from the manufacturer or re-
placement parts authorised by
the manufacturer.

Electrical safety:

Caution: to avoid accidents
and injuries from electric
shocks:
• The plug and socket of an
extension cable must be water-
tight!
Unsuitable extension cables
can be dangerous as people
can be harmed by an electric
shock!
• Protect the electric plug connec-
tions against moisture.
• If there is a risk of flooding, fix
the plug connections in an area
that is safe from flooding.
• Ensure that the mains voltage
matches the specifications on
the rating plate.
• The electrical installation shall
be according to national wiring
rules.
• Connection to the mains must
be carried out by an experi-
enced electrician and meet the
requirements of IEC 60364-1.
• The device must only be con-
nected to a mains socket via a
residual-current circuit breaker
(RCD) with a rated leakage cur-
rent of not more than 30 mA.
Fuse: at least 13 ampere.
• Before each use, check the
equipment, cable and plug for
damage.
• If the power cable for this